Vickers CPF2S 10 F H 3S M U

Description & Features

Designed for applications requiring adjustable pressure relief, the Vickers CPF2S 10 F H 3S M U pressure control valve is a reliable choice for managing hydraulic circuit pressure with precision. Its plug-and-play design ensures ease of installation, while high-performance features contribute to optimal system efficiency. With a robust flow rate capacity of 600 liters per minute, this valve is ideal for demanding industrial environments.

Constructed with durable Buna-N seal material, the Vickers CPF2S 10 F H 3S M U valve offers moisture resistance, enhancing its longevity in challenging conditions. It fits seamlessly into systems that require precise pressure regulation, ensuring safety and reliability. The valve's compact width of 6.57 inches makes it suitable for various configurations without compromising space.

SKU: 02-310240

Supplier Part Number (MPN): 02-310240

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X47365
Application
Applications requiring an adjustable pressure relief or regulating valve to limit the pressure in a hydraulic circuit to a desired maximum
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Plug-and-play design|High-performance features|Moisture resistant
Flow Rate1
600 litre per minute
ICC
IV Pressure Valves
Language
English
Product Width
6.57
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-310240
Wattage
30
Product Weight
21.00 lbs

Product Questions & Answers (2)

Question by: Brent G on May 1, 2025, 6:20 PM
I'm looking to swap out an old valve. What's the width on this Vickers CPF2S 10 F H 3S M U? Just need to make sure it'll fit without redoing all the hydraulic connections.
Answer by: Customer Support on May 3, 2025, 6:55 AM
This valve has a width of 6.57 inches, making it suitable for installations with space constraints. It's designed to fit seamlessly into existing systems.
Question by: Brent R on Aug 4, 2025, 4:07 PM
flow rate on this thing is listed at 600 liters per minute -- that accurate for continuous pressure relief work or is that more of a peak figure?
Answer by: Customer Support on Aug 5, 2025, 9:26 PM
600 liters per minute is the rated flow capacity for this valve. For a pressure control application like this one, where the valve is limiting circuit pressure to a set maximum, that rating reflects what the valve is built to handle. It's a solid capacity for demanding industrial setups that need consistent pressure regulation without throttling performance.