Vickers CPF2S 06 F W 3S M

Description & Features

Designed for hydraulic circuits requiring precise pressure management, the Vickers CPF2S 06 F W 3S M is an adjustable pressure relief and regulating valve built to limit system pressure to a defined maximum. Manufactured under the Vickers brand by Danfoss/Eaton, this valve is suited to applications where consistent, controllable pressure control is critical.

Rated for flow up to 100 litres per minute and 30 watts, the valve features a plug-and-play design for straightforward installation and integration. Buna-N seals provide reliable performance across a broad range of hydraulic fluids, while moisture-resistant construction supports use in demanding industrial environments. No special features or auxiliary options are configured on this unit.

SKU: 02-310334

Supplier Part Number (MPN): 02-310334

Specifications

Actuator Type
Solenoid
Adjustment Type
Screw with Locknut
Body Material
Iron
Connection Type
SAE
Design
20 Series
Dimensions
5.5 in L x 2.5 in W x 7.09 in H
Domestic/Import
Domestic
Drain
Internal
Electrical Connection
1/2 in NPT Flying Leads Terminal Block
End Type
SAE
Gauge Port Thread
1/4 in BSP
Hi-Vent Spring
Without Hi-Vent Spring
Indicator Light
With Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Nominal Size
3/4 in
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Series
CPF2S-06 Series
Valve Mount Type
Flange-Mounted
Voltage Rating
110 VAC at 50 Hz, 120 VAC at 60 Hz

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Daryl M on Mar 16, 2026, 10:14 AM
flow rate on this valve is listed at 100 litres per minute -- is that enough for most standard industrial hydraulic circuits, or is this more of a light-duty unit?
Answer by: Customer Support on Mar 18, 2026, 9:29 AM
For a good chunk of industrial hydraulic setups, 100 litres per minute is a solid working capacity. It handles pressure relief and regulation duties without being a bottleneck in moderate-flow systems. Where you'd want to think twice is in high-demand circuits running consistently above that threshold. As long as your system stays within that flow ceiling, this valve is built to manage pressure limits reliably.