VICKERS CVI 50 HFV 20 B 130 10

Description & Features

Vickers CVI 50 HFV 20 B 130 10 is a slip-in cartridge valve insert designed for versatile and demanding applications. With a robust flow rate of 2350 liters per minute, it is ideal for use in presses, plastics molding machines, die casting machines, shears and balers, machine tools, metal forming, and steel mill machinery, as well as mobile vehicles and marine environments. This valve ensures efficient and dependable operation with its best-in-class design, providing faster response times crucial for high-performance machinery.

Constructed with durable Buna-N seal material, the Vickers CVI 50 HFV 20 B 130 10 offers reliability and longevity in challenging industrial conditions. Its compact design, with a product width of 3.54 inches, allows for seamless integration into existing systems where space and performance are critical factors. Manufactured under the reputable Vickers brand by Danfoss/Eaton, this valve is a trusted choice for enhancing system efficiency and performance.

SKU: 02-312102

Supplier Part Number (MPN): 02-312102

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900J00137
Application
Presses, Plastics Molding Machines, Die Casting Machines, Shears and Balers, Machine Tools and Metal Forming Machinery, Steel Mill Machinery and other Primary Metal Processing Equipment, Mobile Vehicle, and Marine
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Efficient, dependable operation|Best-in-class design|Faster response time
Flow Rate1
2350 litre per minute
ICC
IV Slip-in Valves
Language
English
Net Pack Quantity Units
EA
Product Width
3.54
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-312102
Product Weight
4.80 lbs

Product Questions & Answers (2)

Question by: Norm K on Nov 12, 2025, 3:02 PM
What size opening does this cartridge valve need?
Answer by: Customer Support on Nov 13, 2025, 4:49 PM
It's got a width of 3.54 inches, so you'll need an opening just a bit bigger than that to allow it to slip in properly. Make sure to double-check your measurements to avoid any headaches during installation.
Question by: Judy M on Apr 6, 2025, 2:15 PM
flow rate on this thing is listed at 2350 liters per minute, is that enough to run a hydraulic press without bottlenecking the system?
Answer by: Customer Support on Apr 8, 2025, 6:58 AM
For most press applications, 2350 liters per minute is a substantial flow capacity. That puts it well above what the majority of industrial press circuits demand, so bottlenecking at the valve itself generally won't be your concern. It's worth making sure your lines, manifold, and pump are sized to match, but the valve won't be the weak point in a well-built system.