VICKERS PVH074R01AA10B252000001001AE010A

Description & Features

Ideal for demanding industrial environments, the Vickers PVH074R01AA10B252000001001AE010A is a robust open circuit piston pump designed for applications such as mining machinery, injection molding machines, and oil and gas equipment. Its durable construction and long-lasting performance make it a reliable choice for primary metals and metal forming machines. The pump features torque-limiting capabilities and a Q250 valve plate, ensuring efficient operation without a case to inlet check valve.

This Vickers pump is engineered for mobile applications, providing versatility and high performance in various settings, including conveyor lines and metal cutting equipment. With a width of 8.82 inches, it fits seamlessly into existing systems, offering easy integration and maintenance. The product's lead time is 110 days, reflecting its specialized manufacturing process and quality assurance standards.

SKU: 02-315215

Supplier Part Number (MPN): 02-315215

Specifications

Brand
Vickers by Danfoss
Control Type
Pressure and Flow Compensator
Controller Type
Pressure and Flow Compensator
Design Code
A
Dimensions
14.27 in L x 8.82 in W x 10.59 in H
Drive Shaft Type
Keyed
Housing Material
Iron
Input Shaft Rotation
Clockwise (Right-Hand) Right Side Suction Port, Left Side Pressure Port
Maximum Displacement Option
Standard Displacement
Mounting Type
4-Bolt Flanged
nmfc
125820
Pressure Compensator Setting
246 to 254
Rotation Direction
Clockwise (Right Hand)
Seal Material
Fluorocarbon
Segment Code
C
Series
PVH Series

Product Questions & Answers (2)

Question by: Neal R on Nov 9, 2025, 1:42 PM
Hey, is this pump gonna hold up if I'm running it pretty much all day, every day?
Answer by: Customer Support on Nov 11, 2025, 6:02 AM
Designed for demanding industrial environments, this Vickers pump features durable construction that makes it a reliable choice for continuous operation in applications like mining and metal forming.
Question by: Brett B on Sep 29, 2025, 7:15 AM
pump's got a Q250 valve plate listed but no case to inlet check valve, does that affect how it needs to be plumbed into an existing system?
Answer by: Customer Support on Sep 30, 2025, 12:05 PM
Worth paying attention to during installation. Without a case to inlet check valve, the drain line configuration needs to be handled carefully so the case doesn't run dry on startup or during low-pressure transitions. The Q250 valve plate is a specific flow and timing configuration, so if you're swapping this into a system that previously ran a different plate spec, expect to verify your timing and flow characteristics match up before calling it done.