VICKERS PVH98C RAF 2S 11 C25V 31 036

Description & Features

Designed for demanding industrial environments, the Vickers PVH98C RAF 2S 11 C25V 31 036 is an open circuit piston pump built to handle the rigorous load cycles common in metal forming, injection molding, oil and gas equipment, and primary metals processing. It is also well-suited for use in mining machinery, metal cutting equipment, and conveyor line applications.

This pump is part of the Danfoss/Eaton PVH Series, a line recognized for durable construction and torque-limiting capabilities that help protect drive components under variable load conditions. Long-term reliability across high-demand duty cycles is a core characteristic of this series, making it a practical choice where consistent hydraulic output is critical.

With a product width of 9.17 inches, this unit fits within standard mounting configurations typical of mobile and stationary industrial hydraulic circuits.

SKU: 02-315283

Supplier Part Number (MPN): 02-315283

Specifications

Brand
Vickers by Danfoss
Code Title
Vickers Pressure Compensated/Pressure Flow Compensated Open Circuit Piston Pump
Control Type
Pressure and Flow Compensator
Design Code
A
Dimensions
14.94 in L x 9.17 in W x 10.77 in H
Drain Port Size Location
7/8-14 UNF-2B SAE O-ring Port - Bottom (Top Plugged)
Drive Shaft Type
Splined
Front Mounting Input Shaft
4-Bolt C (SAE J744-127-4) with 14T 12/24 DP Splined Shaft, 56 mm [2.2 in] Shaft Extension
Housing Material
Iron
Main Ports Size Location
Side Ports, Suction - 2-1/2 SAE 4 Bolt Split Flanged Port Standard Pressure Series (Code 61) with 1/2-13 UNC-2B Threads, Pressure - 1 SAE 4 Bolt Split Flanged Port Standard Pressure Series (Code 61) with 3/8-16 UNC-2B Threads
Mounting Type
2-Bolt Flanged
nmfc
125820
Pressure Compensator Setting
246 to 254
Rotation Direction
Clockwise (Right Hand)
Seal Material
Fluorocarbon
Segment Code
C
Series
PVH Series

Product Questions & Answers (1)

Question by: Scott W on Jan 8, 2026, 11:09 AM
We run injection molding equipment pretty much around the clock and been burning through pumps faster than we'd like. This a pump that can hold up to that kind of steady workload?
Answer by: Customer Support on Jan 9, 2026, 9:35 PM
Long-duration, high-demand duty cycles are exactly where the PVH Series earns its keep. Vickers built this line with durability as a primary focus, and it's recognized specifically for holding up under the kind of repetitive load cycles you see in injection molding environments. The torque-limiting capability is worth noting too, because it helps protect your drive components when loads spike, which tends to be a big contributor to premature pump wear in continuous-run setups.