Vickers CPF2S 08 F W 3S M

Description & Features

Designed for applications requiring adjustable pressure relief or regulation, the Vickers CPF2S 08 F W 3S M pressure control valve is an ideal choice for maintaining desired maximum pressures within hydraulic circuits. With a robust flow rate of 300 liters per minute, this valve ensures efficient performance in demanding environments. The plug-and-play design, combined with high-performance features, offers seamless integration and reliable operation.

Constructed with moisture-resistant materials and featuring a Buna-N seal, this valve promises durability and longevity in various industrial settings. As a sub-brand of Vickers, it carries the legacy of quality and reliability. The valve’s compact design, with a width of 6.07 inches, makes it suitable for space-constrained installations. Rated at 30 watts, it balances power consumption with performance efficiency.

SKU: 02-316407

Supplier Part Number (MPN): 02-316407

Specifications

Actuator Type
Solenoid
Adjustment Type
Screw with Locknut
Body Material
Iron
Connection Type
SAE
Design
20 Series
Dimensions
5.68 in L x 6.07 in W x 7.09 in H
Domestic/Import
Domestic
Drain
Internal
Electrical Connection
1/2 in NPT Housing Flying Leads
End Type
SAE
Gauge Port Thread
1/4 in BSP
Hi-Vent Spring
Without Hi-Vent Spring
Indicator Light
Without Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Nominal Size
1 in
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Series
CPF2S-08 Series
Valve Mount Type
Flange-Mounted
Voltage Rating
110 VAC at 50 Hz, 120 VAC at 60 Hz

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Lee M on Oct 14, 2025, 4:02 PM
Flow rate on this thing is listed at 300 liters per minute, that enough to keep up with a high-demand circuit without the valve becoming a bottleneck?
Answer by: Customer Support on Oct 16, 2025, 6:34 AM
For most industrial hydraulic circuits pulling heavy load cycles, 300 liters per minute gives you solid headroom. That capacity is built to handle demanding environments without the valve restricting flow and causing pressure instability upstream. If your system is running anywhere near that ceiling consistently, the adjustable pressure relief function also lets you dial in your maximum pressure setpoint so the circuit stays where you need it rather than spiking unpredictably.