Vickers CG5 H060A FV M FTWL

Description & Features

Designed for applications requiring adjustable pressure relief or regulation, the Vickers CG5 H060A FV M FTWL is engineered to limit pressure within a hydraulic circuit to a desired maximum. This pressure valve offers a plug-and-play design, moisture resistance, and high-performance features.

This Vickers valve has a maximum flow rate of 340 liters per minute and uses Buna-N seals. It measures 2.81 inches wide.

SKU: 02-324180

Supplier Part Number (MPN): 02-324180

Specifications

Actuator Type
Pilot Operated, Solenoid
Adjustment Type
Screw with Locknut
Body Material
Iron
Design
100 Series
Dimensions
5.75 in L x 2.81 in W x 9.65 in H
Domestic/Import
Domestic
Electrical Connection
1/2 in NPT Flying Leads Terminal Block
Hi-Vent Spring
With Hi-Vent Spring
Indicator Light
With Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Nominal Size
#06
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Series
CG5-06 Series
Spring Arrangement
Spring Offset
Valve Mount Type
Subplate/Manifold
Voltage Rating
110 VAC at 50 Hz, 120 VAC at 60 Hz

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Travis C on Apr 22, 2025, 10:07 AM
flow rate on this thing listed as 340 liters per minute, that enough to handle high-demand circuits without choking the system?
Answer by: Customer Support on Apr 24, 2025, 8:13 AM
For most high-demand hydraulic circuits, 340 liters per minute gives you solid headroom. That kind of flow capacity puts this valve in range for heavy industrial and mobile applications where you need a pressure relief or regulating valve that can keep up without becoming a bottleneck. It's built to limit circuit pressure to a set maximum, so as long as your system's peak flow stays within that 340 LPM ceiling, you're in good shape.
Question by: Dustin S on Apr 13, 2025, 7:26 AM
Is this the right valve if I need to keep the pressure in my hydraulic system from going too high?
Answer by: Customer Support on Apr 14, 2025, 1:46 PM
Designed for applications requiring adjustable pressure relief or regulation, this Vickers valve is engineered to limit pressure within a hydraulic circuit to a desired maximum.

Tell us what you need and we'll get back to you.

Fields marked * are required.