VICKERS 25VQS21C297C20L

Description & Features

Built for high-pressure, high-speed hydraulic applications, the Vickers 25VQS21C297C20L is a vane pump from the 25VQ series, manufactured under the Vickers by Danfoss/Eaton brand. Cast iron construction provides durability across demanding industrial environments, while Buna-N seals deliver reliable fluid compatibility with standard hydraulic oils.

With a flow rate of approximately 148.7 litres per minute, this pump is well suited for metal cutting machinery, plastic injection molding equipment, dump trucks, wheel loaders, and oil and gas applications. The 25VQ series is recognized for strong volumetric efficiency and extended service life, making it a practical choice where consistent output under sustained load is required.

SKU: 02-328052-7

Supplier Part Number (MPN): 02-328052-7

Specifications

Brand
Vickers by Danfoss
Cartridge Type
Industry-First Intra-Vane
Design Code
20
Dimensions
8.08 in L x 6.87 in W x 5.4 in H
Drive Shaft Type
Splined
Housing Material
Iron
Inlet Type
Flanged
Maximum Operating Pressure
3000 psi
Model
25VQ
Mounting Type
Flanged
Outlet Type
Threaded
Rotation Direction
Counterclockwise
Seal Material
Nitrile
Series
VQ Series
Vane Type
Fixed Displacement

Similar Products

Model Number Displacement Flow Rate Speed Rating Price Action
VICKERS-25VQS12C 297D20L

02-160141-8

Product Questions & Answers (2)

Question by: Shawn W on Jan 18, 2026, 7:02 AM
Just wanna be sure, this pump is cast iron right?
Answer by: Customer Support on Jan 19, 2026, 10:29 AM
The 25VQS21C297C20L vane pump uses a cast iron construction. This gives it the durability needed for demanding industrial environments.
Question by: Hugh G on Feb 1, 2026, 11:10 AM
Flow rate on this one shows around 148 liters a minute, that right for the 25VQ series, or is that just a peak number?
Answer by: Customer Support on Feb 3, 2026, 6:31 AM
That 148.69 litres per minute figure is the rated flow for this pump, not a peak or burst rating. The 25VQ series is built around consistent output under sustained load, so that number reflects what you can expect during normal operation rather than a ceiling it occasionally touches.