The Vickers DG5V8S2ALMUH10 directional control valve is a two-stage valve suitable for applications such as die casting and foundry work, machine tools, marine and offshore environments, presses, primary metal production, paper mills, test equipment and simulation, and turbine control systems (wind, steam, and water).
This Vickers valve features three- or four-way directional control and is easily mountable on industry-standard surfaces. It has a maximum flow rate of 700 litres per minute and utilizes Buna-N seals.
SKU: 02-330941
Supplier Part Number (MPN): 02-330941
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X48772
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Three- or four-way directional control|Easily mountable on industry-standard surfaces|Thousands of models to suit all applications
Flow Rate1
700 litre per minute
ICC
IV Directional Control Valves
Language
English
Product Width
4.67
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-330941
Product Weight
19.60 lbs
Product Questions & Answers (2)
Question by: Hubert R on Jun 17, 2025, 11:25 AM
Will this directional valve hold up in a marine environment, out on the coast?
Answer by: Customer Support on Jun 18, 2025, 12:21 PM
Designed for marine and offshore environments, this Vickers valve should provide reliable directional control. Just be sure to follow recommended maintenance schedules, as saltwater can be tough on any equipment over time.
Question by: Hubert C on Jul 9, 2025, 3:37 PM
Got a press setup running pretty high flow demands. This valve handle anything up to 700 LPM or is that more of a peak rating?
Answer by: Customer Support on Jul 11, 2025, 12:45 PM
Seven hundred litres per minute is the maximum flow rate for this valve, so yes, it covers high-demand press applications. That figure represents the upper limit, not a continuous operating guarantee, so sizing your system with some headroom below that ceiling is good practice. Press work is actually one of the listed application types for this valve, so it fits well in that kind of environment.