VICKERS DG4V4013CMUB510

Description & Features

Designed for demanding industrial environments, the Vickers DG4V4013CMUB510 is a single-stage directional control valve capable of handling flow rates up to 115 litres per minute. It supports both three- and four-way directional control configurations, making it adaptable across a wide range of hydraulic circuit designs.

Buna-N seals provide reliable fluid compatibility in standard hydraulic media, and the 30-watt solenoid rating suits common industrial power supplies. Mounting follows industry-standard surface patterns, simplifying integration into new or existing hydraulic systems. Suitable applications span machine tool, press, primary metal, marine and offshore, die casting and foundry, test and simulation equipment, and turbine control, including wind, steam, and water turbine installations. The broad application range reflects the valve's design flexibility across high-cycle and precision-control environments alike.

SKU: 02-337544

Supplier Part Number (MPN): 02-337544

Specifications

Brand
Vickers by Danfoss
Actuator Type
Solenoid
Design
10 Series
Dimensions
9.38 in L x 2.84 in W x 4.31 in H
Domestic/Import
Domestic
Indicator Light
Without Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Number of Stages
1
Performance
Standard
Seal Material
Buna-N
Segment Code
C
Series
DG4V4-01 10 Series
Spool Position Monitor
Without Spool Position Monitor
Spool Type
Spool 3
Spring Arrangement
Spring Centered
Surge Suppressor Damper
Without Surge Suppressor Damper
Valve Mount Type
Subplate/Manifold

Product Questions & Answers (2)

Question by: Danny J on Jul 24, 2025, 6:06 AM
If I'm swapping out an old valve, is this one gonna fit without a bunch of extra hassle?
Answer by: Customer Support on Jul 25, 2025, 3:42 PM
Mounting this valve is usually straightforward since it follows industry-standard surface patterns. Integration into existing hydraulic systems shouldn't be too complicated.
Question by: Rick W on Aug 31, 2025, 11:34 AM
Flow rate on this one shows 115 litres per minute, that enough to run a press line without starving the circuit?
Answer by: Customer Support on Sep 1, 2025, 6:55 PM
For most press applications, 115 LPM gives you solid throughput. This valve was built with press environments in mind alongside machine tool and primary metal work, so the flow capacity aligns well with those kinds of demands. As long as your system is sized to match that flow ceiling, you shouldn't run into starvation issues on a standard press circuit.