VICKERS CPF2S 12 B W 1 3S M U D5 20

Description & Features

Designed for hydraulic circuits requiring precise pressure management, the Vickers CPF2S 12 B W 1 3S M U D5 20 is an adjustable pressure control valve built to limit system pressure to a set maximum. It handles flow rates up to 800 litres per minute, making it well suited to demanding industrial hydraulic applications where consistent pressure regulation is critical.

The valve features a plug-and-play design for straightforward installation and is constructed with Buna-N seals for reliable fluid compatibility in standard hydraulic media. Moisture-resistant construction supports use in environments where exposure to humidity or contaminants is a concern. Rated at 30 watts, this Vickers unit delivers high-performance pressure control within a robust, industrially rated package.

SKU: 02-342625

Supplier Part Number (MPN): 02-342625

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X49603
Application
Applications requiring an adjustable pressure relief or regulating valve to limit the pressure in a hydraulic circuit to a desired maximum
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Plug-and-play design|High-performance features|Moisture resistant
Flow Rate1
800 litre per minute
ICC
IV Pressure Valves
Language
English
Product Width
6.50
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-342625
Wattage
30
Product Weight
24.30 lbs

Product Questions & Answers (2)

Question by: Janice C on Apr 15, 2025, 4:02 PM
Got a high-flow hydraulic circuit that keeps spiking past where we want it. This valve rated to handle something like 800 litres per minute, or is that pushing it?
Answer by: Customer Support on Apr 17, 2025, 7:58 AM
800 litres per minute is the rated flow capacity on this unit, so if your system stays at or under that, you're in good shape for consistent pressure regulation. It's built for demanding industrial applications where holding a set pressure ceiling matters, and the adjustable design lets you dial in your target maximum rather than being locked to a fixed value. Good fit for high-flow setups where pressure spikes are a real concern.
Question by: Daryl C on Jul 18, 2025, 7:16 PM
Reckon this valve can handle gettin' a little wet in the shop?
Answer by: Customer Support on Jul 20, 2025, 8:34 AM
With its moisture-resistant construction, this Vickers valve is designed to hold up in environments where humidity or contaminants might be present.