An open-circuit piston pump built for demanding industrial hydraulic applications, the Vickers PVM131ER12GS02AAC28110000A0A is a variable-displacement unit rated for high-pressure service across a range of industrial machinery and mobile equipment platforms. It falls within Vickers' PVM series, which is widely used in systems requiring precise flow control and reliable performance under variable load conditions.
This unit includes an adjustable maximum displacement stop, allowing technicians to mechanically limit the pump's displacement output without software intervention, a practical feature for system calibration and protection. The pump contains a single shaft seal. At 9.55 inches in width, it is sized for mid-to-large frame hydraulic circuit configurations.
SKU: 02-346202
Supplier Part Number (MPN): 02-346202
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900H67291
Brand
DANFOSS POWER SOLUTIONS II LLC (VICKERS)
Brand
Vickers
Pack Size
1.00
UOM
EA
ICC
Industrial - OC Piston Pumps
Language
English
Product Width
9.55
Special Features
Adjustable Max Displacement Stop (Contains Single Shaft Seal)
Supplier Part Number
02-346202
Product Weight
98.00 lbs
Product Questions & Answers (2)
Question by: Rex B on Oct 24, 2025, 3:39 PM
pump's got an adjustable max displacement stop on it, what exactly does that do for me in a real setup?
Answer by: Customer Support on Oct 25, 2025, 9:34 PM
Mechanically limiting the pump's displacement output means you can cap how much flow the unit produces without touching any software or controls. For system calibration or protecting downstream components from seeing more flow than they're built for, that's a pretty practical feature to have built right into the hardware.
Question by: Wes H on Nov 3, 2025, 7:24 AM
What's the story on adjusting the max displacement? Is that something I can tweak myself without needing a bunch of software?
Answer by: Customer Support on Nov 4, 2025, 5:57 PM
That adjustable maximum displacement stop gives you a way to mechanically limit the pump's output. It's a handy feature for calibrating the system and adding a layer of protection, and you won't need to use software to make those adjustments.