Designed for mobile and industrial applications including harvesters and refuse haulers, the Vickers EPV16-A-10-12D-S-F-13 is a poppet-style proportional valve built for demanding flow control requirements. It supports a rated flow of 100 litres per minute, with the EPV16 series capable of handling flows up to 160 L/min (42 USgpm), making it well-suited to high-demand hydraulic circuits.
Operating on a 12-volt supply, this valve combines a compact footprint with flexible installation, minimising space requirements without sacrificing performance. The poppet construction contributes to reliable, consistent operation across varying load and pressure conditions. Part of the Vickers by Eaton EPV16 proportional valve series, it is a practical choice where precise flow proportionality and installation economy are both priorities.
SKU: 02-355072
Supplier Part Number (MPN): 02-355072
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X11725
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Rated flows up to 160 L/min (42 USgpm)|Reliable, economical and compact|Maximum flexibility and minimum space
Flow Rate1
100 litre per minute
ICC
SICV Proportional Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1.71
Special Features
None
Style
Poppet
Sub Brand
Vickers
Supplier Part Number
02-355072
Voltage
12 volt
Product Weight
2.20 lbs
Product Questions & Answers (2)
Question by: Larry M on Jun 5, 2025, 8:20 AM
Is this thing sized right for, say, a harvester running at full tilt?
Answer by: Customer Support on Jun 7, 2025, 6:45 AM
It is designed to handle flows up to 160 liters per minute, making it suitable for demanding hydraulic circuits in equipment like harvesters.
Question by: Janet B on Nov 22, 2025, 5:22 PM
Running a refuse hauler and need proportional flow control that ain't gonna take up half my valve bank. This EPV16 work for that kind of setup?
Answer by: Customer Support on Nov 24, 2025, 6:00 AM
Refuse haulers are actually one of the core applications this valve was built around, so you're in good shape there. The poppet-style construction handles the kind of varied load conditions you'll see on that equipment without losing consistent flow proportionality. Rated at 100 litres per minute with the series capable of going up to 160 L/min, it's got enough capacity for demanding circuits while keeping a compact footprint that won't eat up your available space.