DGMPC3ABK41EN417

Description & Features

The Vickers DGMPC3ABK41EN417 SystemStak Valve by Danfoss is a versatile component designed for machine tool and multiple industrial applications. Engineered with a flow rate of 60 liters per minute, this directional control valve effectively manages hydraulic flow, ensuring optimal system performance. Equipped with Buna-N seals, it offers excellent resistance to external contaminants and leakage, enhancing durability and reliability in demanding environments.

This valve significantly reduces installation costs by eliminating the need for external piping, a common source of leakage and maintenance issues. Its robust design, part of the renowned Vickers sub-brand, underscores a commitment to quality and efficiency, making it a preferred choice in the hydraulic industry.

SKU: 02-355848

Supplier Part Number (MPN): 02-355848

Specifications

Actuator Type
Pressure Operated
Body Material
Ductile Iron
Configuration
Sandwich Mounted Between a Directional Valve and a Standard Mounting Surface
Design Series
41 Series
Dimensions
3.82 in L x 1 in W x 1.57 in H
Media
Mineral Oil
Mounting Type
Manifold, Subplate
Operator Type
Pilot Operated
Seal Material
FKM
Series
DGMPC-3-41 Series
Softgoods Material
FKM

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Rick H on Dec 19, 2025, 4:15 PM
Flow rate on this one says 60 liters per minute -- that enough for most machine tool setups or is it usually on the lower end for that kind of work?
Answer by: Customer Support on Dec 20, 2025, 8:15 PM
For machine tool applications, 60 liters per minute is a solid working rate that fits comfortably within the range most standard setups actually call for. It handles the kind of directional control demands you run into in production environments without being overkill. If your system is running unusually high flow demands, you'd want to verify against your circuit requirements, but for typical machine tool use this sits right in the sweet spot.
Question by: Lynn C on Mar 20, 2026, 1:26 PM
Can this valve handle hydraulic fluid with some contamination, or do I need to run a real clean system?
Answer by: Customer Support on Mar 22, 2026, 6:54 AM
Buna-N seals give this directional control valve good resistance to external contaminants, which helps prevent leakage and maintain reliability.