VICKERS DG17V4016C10

Description & Features

The Vickers DG17V4016C10 directional control valve offers a versatile solution for various industrial applications, including die casting, machine tools, and turbine control. Known for its robustness, this valve is suitable for marine, offshore, and primary metal industries. Designed by Eaton Vickers, it features a three- or four-way directional control capability and mounts easily on industry-standard surfaces, ensuring compatibility across a wide range of systems. With a flow rate of 114 liters per minute, this valve is engineered for efficiency and reliable performance. Constructed with Buna-N seals, it provides durability and resistance to various hydraulic fluids.

Ideal for applications requiring precise control, the DG17V4016C10's compact design, measuring 2.75 inches in width, allows for easy integration into existing setups. Backed by the trusted Vickers brand, this valve is part of a comprehensive range of models designed to meet diverse industrial needs. Its straightforward design prioritizes functionality, making it a preferred choice for professionals seeking dependable and high-performing directional control solutions.

SKU: 02-356393

Supplier Part Number (MPN): 02-356393

Alternate Part Numbers: DG17V4016C10

Specifications

Brand
Vickers by Danfoss
Actuator Type
Solenoid, Manual Lever
Design
10 Series
Dimensions
6.9 in L x 2.75 in W x 7.06 in H
Domestic/Import
Domestic
Indicator Light
Without Indicator Light
Language
English
Media
Petroleum Oil
Number of Stages
1
Performance
High-Performance
Seal Material
Buna-N
Series
DG17V4-01 10 Series
Spool Position Monitor
Without Spool Position Monitor
Spool Type
Spool 6
Spring Arrangement
Spring Centered
Surge Suppressor Damper
Without Surge Suppressor Damper
Valve Mount Type
Subplate/Manifold

Product Questions & Answers (1)

Question by: Rod G on Mar 3, 2026, 6:55 PM
flow rate on this one is listed at 114 liters per minute -- is that enough for press applications or would it be cutting it close?
Answer by: Customer Support on Mar 5, 2026, 8:00 AM
For most press setups, 114 liters per minute is a solid working capacity. Press applications are one of the listed uses for this valve, so it falls squarely within the intended range. Whether it's enough depends on your specific circuit demands, but the flow rating is not a marginal or borderline figure for typical press work.

Tell us what you need and we'll get back to you.