Rated for flows up to 80 litres per minute, the Vickers DG4V32AMFWLD7H760EN75 is a solenoid-operated directional control valve designed for demanding industrial hydraulic circuits. The 30-watt solenoid coil and Buna-N seal construction make it well suited for high-cycle service across a broad range of system media and operating conditions.
This valve is applicable across a wide range of industries, including machine tool, press, primary metal, die casting and foundry, marine and offshore, turbine control, and test and simulation equipment. Its versatility across these sectors reflects a design capable of handling the precision and reliability requirements typical of high-duty hydraulic circuits.
SKU: 02-360978
Supplier Part Number (MPN): 02-360978
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X60796
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Flow Rate1
80 litre per minute
ICC
IV Directional Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1.80
Seal Material
Buna-N
Special Features
None
Supplier Part Number
02-360978
Wattage
30
Product Weight
4.00 lbs
Product Questions & Answers (2)
Question by: Howard T on Jun 26, 2025, 8:09 PM
What kind of machines or industries does this directional control valve work with?
Answer by: Customer Support on Jun 28, 2025, 6:35 PM
This Vickers valve is applicable across machine tool, press, primary metal, die casting and foundry, marine and offshore, turbine control, and test and simulation equipment.
Question by: Rusty B on Jan 27, 2026, 5:22 PM
flow rate on this valve is listed at 80 LPM -- we running a press circuit that needs to hit that pretty consistent under load. that gonna hold up or is 80 more of a peak number?
Answer by: Customer Support on Jan 29, 2026, 6:12 AM
80 litres per minute is the rated flow capacity for this valve, so your press circuit should be fine operating at or near that level. Buna-N seals and a 30-watt solenoid coil put this thing together for high-cycle industrial work, and press applications are explicitly in its design envelope. Just make sure your system stays within that flow ceiling and you shouldn't run into issues.