VICKERS DG5V8H33C2MUB10

Description & Features

The Vickers DG5V8H33C2MUB10 is a two-stage directional control valve suitable for various applications including die casting and foundry, machine tools, marine and offshore, press, primary metal, paper, test equipment and simulation, and turbine control (wind, steam, water).

This Vickers valve features three- or four-way directional control and is easily mountable on industry-standard surfaces. It has a maximum flow rate of 700 liters per minute and utilizes Buna-N seals.

SKU: 02-362359

Supplier Part Number (MPN): 02-362359

Specifications

Brand
Vickers by Danfoss
Actuator Type
Solenoid, Pilot Operated
Design
10 Series
Dimensions
10.45 in L x 4.67 in W x 9.36 in H
Domestic/Import
Domestic
Ext Pilot Pressure
Internal
Gauge Port Thread
7/16-20 UNF, SAE Thread
Indicator Light
Without Indicator Light
Int Pilot Drain
External
Manual Override
Plain
Media
Petroleum Oil
Number of Stages
2
Performance
High
Seal Material
Buna-N
Segment Code
C
Series
DG5V-8 10 Series
Spool Control
Pilot Choke Adjustment
Spool Position Monitor
Without Spool Position Monitor
Spool Type
Spool 33
Spring Arrangement
Spring Centered
Surge Suppressor Damper
Without Surge Suppressor Damper
Valve Mount Type
Subplate/Manifold

Product Questions & Answers (2)

Question by: Wade C on Dec 24, 2025, 10:53 AM
Reckon this valve would hold up okay in a machine shop setting? We get a fair amount of coolant and grime floating around.
Answer by: Customer Support on Dec 25, 2025, 12:57 PM
Designed for applications like machine tools, this Vickers valve should perform reliably in a typical machine shop environment, provided that the Buna-N seals are compatible with the specific coolants used.
Question by: Wayne A on Apr 26, 2025, 7:14 PM
Got a press line running some pretty heavy cycles and need to know if this valve can handle 700 LPM or is that just a peak rating?
Answer by: Customer Support on Apr 28, 2025, 6:15 AM
700 liters per minute is the maximum flow rate for this valve, so your system design should account for that ceiling. Press applications are actually one of the listed uses for this model, so the fit makes sense from an application standpoint. Just make sure your system stays at or below that flow rate under load and you should be in good shape.