Designed for demanding industrial environments, the Vickers DG4S4LW010BH60S471 is a single-stage directional control valve offering three- or four-way flow control with a rated flow capacity of 95 litres per minute. Buna-N seals provide reliable fluid compatibility across a broad range of hydraulic media.
This valve mounts easily on industry-standard surfaces, supporting flexible integration across a wide variety of equipment configurations. Suitable applications span machine tools, presses, die casting and foundry equipment, primary metal and paper processing, marine and offshore installations, turbine control systems, including wind, steam, and water, and test and simulation equipment. The DG4S4 platform is available in thousands of model variants, making it a practical choice where application-specific configuration is required.
SKU: 02-362528
Supplier Part Number (MPN): 02-362528
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X60937
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Three- or four-way directional control|Easily mountable on industry-standard surfaces|Thousands of models to suit all applications
Flow Rate1
95 litre per minute
ICC
IV Directional Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
2.58
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-362528
Product Weight
10.00 lbs
Product Questions & Answers (2)
Question by: Phil T on Jan 20, 2026, 9:40 AM
What kind of hydraulic fluid does this take?
Answer by: Customer Support on Jan 21, 2026, 2:27 PM
Buna-N seals make it compatible with a broad range of hydraulic fluids.
Question by: Diane M on Sep 6, 2025, 10:05 AM
Flow rate on this one says 95 litres per minute, that enough to run a press application without choking the system?
Answer by: Customer Support on Sep 8, 2025, 6:08 AM
For press applications, 95 litres per minute is a solid flow capacity and falls well within the range this valve is built to handle. Press equipment is explicitly listed among the intended applications, so you're not pushing it into territory it wasn't meant for. As long as your system demand stays within that rated flow, you shouldn't run into restriction issues on the valve side.