VICKERS DG17V40133C10

Description & Features

The Vickers DG17V40133C10 directional control valve is engineered for precision in diverse industrial applications such as die casting, machine tools, and turbine control. With a flow rate of 114 liters per minute, this valve ensures efficient hydraulic management. Constructed with a three- or four-way directional control, it offers flexible operation tailored to specific requirements. The valve is mountable on industry-standard surfaces, simplifying integration into existing systems.

Featuring durable Buna-N seals, the Vickers DG17V40133C10 is built to withstand demanding environments. It is ideal for use in marine and offshore settings, primary metal processing, and paper industries. Its compatibility with thousands of models makes it a versatile choice for varied industrial needs.

SKU: 02-390540

Supplier Part Number (MPN): 02-390540

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900H13535
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Three- or four-way directional control|Easily mountable on industry-standard surfaces|Thousands of models to suit all applications
Flow Rate1
114 litre per minute
ICC
IV Directional Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
2.75
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-390540
Product Weight
7.40 lbs

Product Questions & Answers (1)

Question by: Dwayne G on Sep 16, 2025, 12:28 PM
flow rate on this valve is listed at 114 liters per minute -- that enough for press and die casting work or is it gonna be tight?
Answer by: Customer Support on Sep 18, 2025, 12:11 PM
For die casting and press applications, 114 liters per minute is a solid working flow rate. Vickers built this valve with exactly those environments in mind, so you're not forcing a general-purpose part into a specialized role. As long as your system demand stays within that range, you should have plenty of capacity to run those use without starving the circuit.