VICKERS DG5V8H0CSMFWB10

Description & Features

Designed for versatility, the Vickers DG5V8H0CSMFWB10 directional control valve is an essential component in diverse applications such as die casting, machine tools, and marine use. This valve supports three- or four-way directional control, enabling efficient management of hydraulic flow across various industrial settings. With a substantial flow rate of 700 liters per minute, it is engineered to meet high-demand requirements.

The valve's Buna-N seal material ensures durability and reliability, making it suitable for demanding environments like primary metal processing and turbine control. Its compatibility with industry-standard surfaces allows for seamless integration into existing systems. The Vickers DG5V8H0CSMFWB10 is part of the IV Directional Control Valves series, known for its extensive range of models that cater to specific industrial needs.

SKU: 02-391063

Supplier Part Number (MPN): 02-391063

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900H10142
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Three- or four-way directional control|Easily mountable on industry-standard surfaces|Thousands of models to suit all applications
Flow Rate1
700 litre per minute
ICC
IV Directional Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
4.67
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-391063
Product Weight
20.00 lbs

Product Questions & Answers (1)

Question by: Clint B on Jul 11, 2025, 1:41 PM
flow rate on this thing says 700 liters per minute -- that accurate for what i'd be running on a press line?
Answer by: Customer Support on Jul 12, 2025, 3:44 PM
700 liters per minute is the rated flow for this valve, so yes, it holds up for high-demand press applications. That capacity puts it well within range for heavy industrial press work, which is one of the listed applications. If your system is pushing near that ceiling consistently, just make sure your circuit design accounts for pressure drop across the valve at full flow.