VICKERS DG4V4016CMUH510S324

Description & Features

Designed for demanding industrial hydraulic circuits, the Vickers DG4V4016CMUH510S324 is a single-stage directional control valve capable of handling flow rates up to 115 litres per minute. Operating at 30 watts, it supports both three- and four-way directional control configurations, making it adaptable across a wide range of system layouts.

Buna-N seals provide reliable fluid compatibility in standard hydraulic media, and the valve mounts easily on industry-standard surfaces to simplify integration into existing equipment. Suitable applications include machine tools, presses, die casting and foundry equipment, marine and offshore systems, primary metal and paper processing, turbine control, and test and simulation equipment. The broad application range reflects the flexibility of the DG4V-4 series platform across heavy industrial environments.

SKU: 02-394866

Supplier Part Number (MPN): 02-394866

Alternate Part Numbers: DG4V4016CMUH510S324

Specifications

Brand
Vickers by Danfoss
Actuator Type
Solenoid
Design
10 Series
Dimensions
12.47 in L x 2.84 in W x 4.31 in H
Domestic/Import
Domestic
Indicator Light
Without Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Number of Stages
1
Performance
Standard
Seal Material
Buna-N
Segment Code
C
Series
DG4V4-01 10 Series
Spool Position Monitor
Without Spool Position Monitor
Spool Type
Spool 6
Spring Arrangement
Spring Centered
Surge Suppressor Damper
Without Surge Suppressor Damper
Valve Mount Type
Subplate/Manifold

Product Questions & Answers (1)

Question by: Earl P on Aug 27, 2025, 1:32 PM
Flow rate on this one says 115 litres per minute, that enough to run a press circuit without starving the actuator?
Answer by: Customer Support on Aug 28, 2025, 2:52 PM
For most press applications, 115 LPM is plenty of capacity through a valve in this class. The DG4V-4 series was built with heavy industrial use in mind, and press systems are actually one of the named applications it's suited for. As long as your system demand stays within that flow ceiling, you shouldn't see pressure drop issues or sluggish actuator response from the valve itself.

Tell us what you need and we'll get back to you.