VICKERS-DGMX2-5-PA-GK-S-30

Description & Features

Designed for machine tool and broader industrial use, the VICKERS-DGMX2-5-PA-GK-S-30 is a SystemStak directional control valve from Vickers by Danfoss/Eaton, built around a stackable manifold architecture that reduces installation complexity by eliminating the need for individual valve interconnection hardware. Rated for flow up to 120 litres per minute, it handles demanding hydraulic circuit requirements with a compact, integrated form factor.

Buna-N seals provide reliable resistance to common hydraulic fluids while supporting contamination resistance in industrial environments. The stacked valve design eliminates external leakage points between circuit elements, a practical advantage in applications where fluid containment and system cleanliness are priorities. With a product width of 2.82 inches, the valve fits within space-constrained manifold assemblies typical of machine tool installations.

SKU: 02-401227

Supplier Part Number (MPN): 02-401227

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X52726
Application
Machine tool and multiple industrial applications
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Reduce installation costs|Eliminate external leakage|Boost resistance to contamination
Flow Rate1
120 litre per minute
ICC
IV Directional Control Valves
Language
English
Product Width
2.82
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-401227
Product Weight
10.00 lbs

Product Questions & Answers (2)

Question by: Earl P on Mar 26, 2026, 8:56 AM
Will this stack on other Vickers valves I already have?
Answer by: Customer Support on Mar 28, 2026, 6:10 AM
It's built using the SystemStak architecture, so it's designed to integrate directly with other SystemStak components, eliminating the need for extra connecting hardware.
Question by: Marvin L on Oct 22, 2025, 10:37 AM
Flow rate on this one says 120 litres per minute, is that enough to handle a busy machine tool circuit without bogging down?
Answer by: Customer Support on Oct 24, 2025, 9:15 AM
For most machine tool hydraulic circuits, 120 litres per minute is solid capacity. That figure puts it well within range for demanding industrial setups where you need consistent flow without pressure drop issues slowing things down. The stackable manifold design also helps here because it cuts down on the interconnect hardware that can sometimes create flow restrictions in more traditional hydraulic connections arrangements.