VICKERS DG4V3S2CMX4H760HAVANT

Description & Features

The Vickers DG4V3S2CMX4H760HAVANT directional control valve is suitable for applications such as die casting, foundry work, machine tools, marine/offshore, press use, primary metal processing, paper mills, test equipment and simulation, and turbine control (wind, steam, and water).

This Vickers sub-brand valve offers three- or four-way directional control and easy mounting on industry-standard surfaces. With a flow rate of 40 liters per minute, this model is constructed with Buna-N seals and requires 30 watts of power.

SKU: 02-413179

Supplier Part Number (MPN): 02-413179

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X52978
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Three- or four-way directional control|Easily mountable on industry-standard surfaces|Thousands of models to suit all applications
Flow Rate1
40 litre per minute
ICC
IV Directional Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
2
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-413179
Wattage
30
Product Weight
4.40 lbs

Product Questions & Answers (1)

Question by: Jean J on Aug 4, 2025, 8:35 AM
Flow rate on this one is listed at 40 liters per minute, is that gonna hold up runnin it on a press setup, or is that pushin the limits of what this valve's built for?
Answer by: Customer Support on Aug 5, 2025, 7:45 PM
Press applications are actually one of the listed uses for this valve, so 40 liters per minute fits right in with that kind of work. It handles three- or four-way directional control, which is exactly what most press circuits need to sequence or shift flow direction. The Buna-N seals hold up well in standard hydraulic fluid environments, and the 30-watt coil isn't a heavy draw on your electrical system. As long as your system design keeps flow within that 40 LPM ceiling, this valve is a solid fit for press use.