10000 Series Geroler Motors, Up to 30460 lb-in Intermittent Torque, 784 Intermittent RPM

Description & Features

Fluid Viscosity Minimum: 70 SUS at operating temperature. Recommended Range: 100-200 SUS.-viscosity
Maximum Case Pressure 300 PSI (Without case drain). For continuous back pressure over 300 PSI, use an external case drain line. Install line so motor case remains full at all times.-case pressure
Maximum Operating Temperature 180° F.-temperature
Recommended Break-In To assure best motor life, run motor for approximately one hour at 30% of rated pressure before application to full load. Be sure motor is filled with fluid prior to any load applications.-break in
Recommended Filtration Per ISO Cleanliness Code, level 18/13.
Recommended Fluids Premium quality, anti-wear type hydraulic fluid.-fluids

Products

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Ralph P on Jul 5, 2025, 4:12 PM
What kind of fluid should I be running in this thing?
Answer by: Customer Support on Jul 7, 2025, 4:00 PM
Premium quality, anti-wear type hydraulic fluid is what's recommended for these motors. You'll want to aim for a viscosity range of 100-200 SUS.

Tell us what you need and we'll get back to you.

Fields marked * are required.