90* Din X Male Npt

Description & Features

Designed for robust hydraulic applications, this 90° elbow adapter efficiently connects DIN tubes and NPT threaded systems. Constructed from durable steel, it ensures reliable performance under demanding conditions. The adapter features an M16 x 1.5 DIN tube connection on one side and a 1/4" - 18 NPTF male thread on the other, offering versatility for various industrial setups. Its compact dimensions include a 14mm width and lengths of 24mm, 17mm, and 27mm, facilitating easy integration into existing systems where space is a premium.

This Adaptall component is engineered for high compatibility with hydraulic systems requiring a secure and precise fit. The 90° shape aids in minimizing flow restrictions while maintaining optimal fluid dynamics. Its robust steel material provides longevity and resistance to wear, making it a reliable choice for industrial environments.

SKU: 5070S-08-04

Supplier Part Number (MPN): 5070S-08-04

Specifications

Connection Size 1
8 mm
Connection Size 2
1/4 in
Connection Type
Male Metric, MNPT
Connection Type 1
Male DIN Tube
Connection Type 2
Male NPT
Dimension Standards
ANSI B1.20.3, DIN 2353
Finish
Zinc-Plated
Fitting Type
90 deg Elbow
Hex Size
14 mm
Material
Steel
Material Construction
Carbon Steel
Series
5070 Series
Thread Size
M16x1.5 x 1/4-18

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Norm A on Nov 25, 2025, 10:04 AM
got a DIN tube line running M16 x 1.5 that needs to tie into a 1/4" NPT port at a right angle, this the right piece for that?
Answer by: Customer Support on Nov 26, 2025, 6:52 PM
That's what this adapter is built for. One end is M16 x 1.5 male DIN tube, the other is 1/4-18 NPTF male thread, and the 90 degree elbow puts those two connections at a right angle to each other. Steel construction, so it holds up in working hydraulic environments. SKU is 5070S-08-04 if you're double-checking against a parts list.

Tell us what you need and we'll get back to you.

Fields marked * are required.