Designed for demanding industrial applications, the Vickers by Danfoss/Eaton PVM Series Open Circuit Piston Pump excels in environments such as mining machinery, injection molding machines, and oil and gas equipment. With its adjustable max displacement stop and single shaft seal, this pump offers precision and reliability. Notable for its 50% noise reduction, it ensures quieter use, enhancing user experience in noise-sensitive settings.
Engineered with outstanding performance standards, the Vickers PVM057ER09GS02AAB2811000AA0A is Pro-FX ready, providing seamless integration into modern hydraulic systems. The robust design and innovative features make it suitable for use in conveyor lines, primary metals, and metal cutting equipment. Its broad compatibility and efficient design make it a versatile choice for various industrial sectors.
SKU: 123AL00285A
Supplier Part Number (MPN): 123AL00285A
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900H65945
Application
Mining Machinery, Injection Molding Machines, Metal Forming Machines, Oil and Gas Equipment, Conveyor Lines, Primary Metals, Metal Cutting Equipment
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
50% less noise|Outstanding performance|Pro-FX ready
ICC
Industrial - OC Piston Pumps
Language
English
Net Pack Quantity Units
EA
NMFC
125820
Product Width
10
Special Features
Adjustable Max Displacement Stop (Contains Single Shaft Seal)
Sub Brand
Vickers
Supplier Part Number
123AL00285A
Product Weight
79.00 lbs
Product Questions & Answers (1)
Question by: Danny R on Jul 24, 2025, 10:06 AM
pump's got the adjustable max displacement stop, does that mean I can dial it back if my system don't need full flow all the time?
Answer by: Customer Support on Jul 26, 2025, 8:31 AM
That's what it's there for. The adjustable max displacement stop lets you set an upper limit on how much flow the pump puts out, so you're not running full bore when the application doesn't call for it. That kind of control comes in handy on equipment where load demands shift around, or where you want to keep heat and wear in check without swapping out the pump entirely.