Designed for demanding low-speed, high-torque hydraulic applications, the Char-Lynn ME Motor ME750BHE DWG #DZA914B is an axial piston motor in the Dowmax ME Series, developed under the Danfoss/Eaton product line. With a torque rating of 3,280 Newton metres, this motor is built to deliver reliable power output where high starting torque and strong overall efficiency are required.

The axial piston design supports high performance at low operating speeds, making it well suited for industrial drive applications that demand consistent torque under variable load conditions. Classified within the industrial low-speed piston motor category, this unit carries the core ME Series characteristics of durable construction and dependable output across a range of mobile and stationary hydraulic systems.

SKU: 134ME00020C

Supplier Part Number (MPN): 134ME00020C

Specifications

Brand
Danfoss
Bearing Type
Roller
Dimensions
22.12 in L x 11.88 in W x 11.69 in H
Mounting Type
Flanged
Seal Material
Nitrile
Series
ME Series
Shaft Type
Splined

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Pete H on Feb 15, 2026, 8:20 AM
What's the torque rating on this Char-Lynn ME motor?
Answer by: Customer Support on Feb 16, 2026, 10:36 AM
This Dowmax ME series axial piston motor delivers a torque rating of 3,280 newton metres.
Question by: Carl T on Oct 27, 2025, 2:38 PM
What kind of torque are we talkin with this motor, and is it enough for heavy industrial drive work?
Answer by: Customer Support on Oct 28, 2025, 7:43 PM
At 3,280 Newton metres, there's plenty of torque on tap for demanding industrial drive applications. The ME750BHE is built around that exact use case, low operating speeds with high torque loads, so it holds up well under the kind of variable load conditions you'd see in heavy equipment or stationary industrial systems. High starting torque is one of its core strengths, so getting a loaded drive moving from a dead stop isn't a concern.

Tell us what you need and we'll get back to you.