06MJ-06FP STRAIGHT

Description & Features

The 06MJ-06FP Straight adapter from Brennan Industries Inc ensures reliable performance in various industrial applications.

Made from high-quality straight steel, this adapter exhibits outstanding durability and resistance to corrosion. The adapter features a Male JIC SAE 37 Degree Flare on one end and a Female NPTF on the other end, adhering to SAE J514 and SAE J476 specifications respectively.

With a maximum dynamic pressure capacity of 6,000 psi, it is designed to withstand demanding conditions. The overall length of the adapter is 1.460 mm, allowing for versatile implementations.

The adapter's precision drilling, with Thread B1 size of 9/16-18 mm and Thread B2 size of 3/8-18 mm, ensures a secure and accurate fit.

Supplier Part Number: 2405-06-06

For California residents, please note the PROP-65 warning.

Specifications

Connection Size 1
3/8 in
Connection Size 2
3/8 in
Connection Type
FNPT, Male JIC
Connection Type 1
Male SAE 37 deg JIC Flare
Connection Type 2
Female SAE NPTF
Dimension Standards
SAE J514, SAE J476
Dimensions
1.46 in L
Finish
Trivalent Zinc-Plated
Fitting Type
Adapter
Hex Size
7/8 in
Material
Steel
Material Construction
12L14/C1045 Steel
Maximum Operating Pressure
6000 psi
Series
2405 Series
Thread 2 Drill Dimensions
0.406 in
Thread B1 Drill Dimensions
0.297 in
Thread B2 Drill Dimensions
0.406 in
Thread Size
3/8-18, 9/16-18

Product Questions & Answers (3)

Sign In Hover me Please sign in to submit a question
Question by: Troy R on Jul 15, 2025, 10:27 AM
Will this here fitting hold up to 6000 psi?
Answer by: Customer Support on Jul 16, 2025, 4:25 PM
Yes, this straight adapter is designed to handle a maximum dynamic pressure of 6,000 psi, so it should work well.
Question by: Harvey H on Mar 22, 2026, 8:15 AM
got a hose with a 6 JIC male on it. is this the piece that’ll let me screw into a 3/8-18 nptf port?
Answer by: Customer Support on Mar 24, 2026, 6:36 AM
Function-wise, yes. One end is a Male JIC SAE 37 degree flare with 9/16-18 threads (SAE J514), and the other end is a Female NPTF with 3/8-18 threads (SAE J476), so it adapts between those two connection types.
Question by: Hank G on Feb 20, 2026, 6:29 AM
What kind of pressure can this fitting hold up to in a working hydraulic line?
Answer by: Customer Support on Feb 21, 2026, 3:19 PM
Rated at 6,000 psi maximum dynamic pressure, it holds up well in demanding hydraulic applications. That rating covers actual working conditions, not just static bench tests, so you've got solid headroom for most industrial setups running standard operating pressures.