Danfoss / Eaton-GR Pump (L2-DIST)

Description & Features

Designed for demanding industrial and mobile hydraulic applications, the Danfoss / Eaton-GR Pump (L2-DIST) is a fixed displacement external gear pump built to deliver reliable performance across a wide range of sectors, including agricultural, civil engineering, material handling, metal forming, and specialty construction.

The Series L2 design incorporates features that address common gear pump limitations: reduced noise and vibration during operation, along with improved volumetric and mechanical efficiency. A field-reversible pump direction adds installation flexibility, while the input drive lubrication orifice in the frontplate supports proper bearing and drive lubrication. The pump is rated for a minimum working temperature of -20°C, making it suitable for cold-climate deployments. A 7-inch product width supports compatibility across standard mounting configurations.

SKU: 25507-LSH

Supplier Part Number (MPN): 25507-LSH

Specifications

Brand
Danfoss
Design Code
A
Dimensions
6.47 in L x 7 in W x 5.95 in H
Gear Type
Single-Stage
Housing Color
Red
Housing Finish
Primer
Housing Material
Aluminum
Identification
Standard
Inlet Size
1-5/8-12
Inlet Type
SAE O-ring
Model
25507
Mounting Type
Flanged
Outlet Size
1-1/16-12
Outlet Type
SAE O-ring
Port Location
Rear
Rotation
Counterclockwise (Left-Hand)
Series
L2 Series
Shaft Type
13 Tooth Splined

Product Questions & Answers (2)

Question by: Melvin J on Jul 13, 2025, 9:33 PM
What kind of work is this pump really meant for? I see some things listed, but what's it *good* at?
Answer by: Customer Support on Jul 15, 2025, 8:21 PM
Specifically, this pump is well-suited for tasks such as agricultural machinery, civil engineering projects, material handling systems, metal forming equipment, specialty construction vehicles, and primary metal production.
Question by: Dustin G on Aug 15, 2025, 6:21 PM
Does this pump hold up when it's running in cold weather conditions, like through a full winter season out in the field?
Answer by: Customer Support on Aug 17, 2025, 6:55 AM
Cold-weather operation is something this unit was built for. The minimum working temperature rating is -20°C, so running it through harsh winter conditions falls well within its design range. Whether it's sitting idle overnight and starting cold in the morning or working through a full shift in freezing temps, that rating gives you a solid baseline for cold-climate deployments.

Tell us what you need and we'll get back to you.