DANFOSS / EATON ACNAR03ADA0010000000000A

Description & Features

Designed for demanding mobile and industrial hydraulic circuits, the Danfoss / Eaton ACNAR03ADA0010000000000A is a fixed displacement external gear pump from the Series 26 platform. It delivers reduced noise and vibration alongside improved volumetric and mechanical efficiency, making it well suited for continuous-duty applications where consistent flow and quiet operation matter.

The pump supports field-reversible rotation direction, adding installation flexibility across a wide range of equipment configurations. Rated for a minimum working temperature of -20°C, it performs reliably in cold-start conditions. Typical applications include tractors and harvesters, machine tools, steering circuits, compactors, sweepers, rotary and reel mowers, lift trucks, fan drive systems, and auxiliary work circuits.

SKU: 26003-RZL

Supplier Part Number (MPN): 26003-RZL

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00287X70216
Application
Tractors & harvesters, Machine tools, Steering circuits, Compactors, Sweepers, Rotary & reel mowers, Lift trucks, Fan drive systems, Auxiliary work circuits
Brand
Danfoss – Hydraulics
Brand
Danfoss Power Solutions
Pack Size
1.00
UOM
EA
Features
Reduced noise and vibration|Improved volumetric and mechanical efficiency|Field reversible pump direction
ICC
Hyd Fixed Dis External Gear Pump
Language
English
Minimum Working Temperature
-20
Product Width
5.12
Special Features
None
Sub Brand
None
Supplier Part Number
26003-RZL
Product Weight
6.00 lbs

Product Questions & Answers (2)

Question by: Rick S on Nov 5, 2025, 2:55 PM
Will this gear pump work okay in cold weather?
Answer by: Customer Support on Nov 6, 2025, 4:02 PM
It's rated for a minimum working temperature of -20°C, so it should handle cold-start conditions without issue.
Question by: Clint B on Jul 16, 2025, 7:29 PM
pump says it's field reversible -- how hard is that to actually do on the job, or is it more of a shop thing?
Answer by: Customer Support on Jul 18, 2025, 6:58 AM
Rotation direction on this pump can be changed without sending it back or swapping out the unit entirely. It's set up so the change can be made in the field, which saves real time when you're fitting it to equipment that runs the shaft the other way. Whether that's a quick job depends on your setup, but it's not meant to require a rebuild or specialized shop equipment to accomplish.