Danfoss / Eaton Cessna Gear Pump ACNAR09AAA0040000000000A

Description & Features

The Danfoss / Eaton Cessna Gear Pump ACNAR09AAA0040000000000A features reduced noise and vibration, along with improved volumetric and mechanical efficiency.

This Eaton Char-Lynn gear pump is field reversible for flow direction, and suitable for tractors, harvesters, machine tools, and steering circuits. Further applications include compactors, sweepers, rotary and reel mowers, lift trucks, fan drive systems, and auxiliary work circuits. It has a minimum working temperature of -20 degrees. Width: 5.12 inches.

SKU: 26009-RZK

Supplier Part Number (MPN): 26009-RZK

Specifications

Brand
Danfoss
Design Code
A
Dimensions
5.16 in L x 5.12 in W x 4.71 in H
Gear Type
Single-Stage
Housing Material
Aluminum
Identification
Standard
Inlet Size
1-1/16-12
Inlet Type
SAE O-ring
Model
26009
Mounting Type
2-Bolt Flanged
Outlet Size
7/8-14
Outlet Type
SAE O-ring
Rotation
Clockwise (Right-Hand)
Series
26 Series
Shaft Type
9 Teeth Splined

Product Questions & Answers (2)

Question by: Norm T on Sep 9, 2025, 10:39 AM
got a tractor with a gear pump setup, would this Danfoss Eaton Cessna Series 26 pump make sense for that kind of job?
Answer by: Customer Support on Sep 11, 2025, 9:28 AM
For tractor and harvester hydraulics, this pump is a common fit in the sense that its listed applications include tractors and harvesters, along with auxiliary work circuits and steering circuits. It is an external gear pump in the Danfoss Power Solutions and Eaton Char-Lynn family, so it lines up with the type of equipment that normally uses a fixed displacement gear pump.
Question by: Larry K on Apr 28, 2025, 6:09 AM
pump says it's field reversible, does that mean I can swap the rotation direction myself out in the shop, or is that more of a factory setup thing?
Answer by: Customer Support on Apr 29, 2025, 7:04 AM
Field reversible means you can change the rotation direction without sending it back anywhere. It's set up to allow that kind of adjustment on-site, so if your circuit runs clockwise or counterclockwise, you've got flexibility to configure it where you're working rather than waiting on a special-order unit.