Danfoss / Eaton-GR Pump (BQR)

Description & Features

Designed for demanding mobile and industrial hydraulic applications, the Danfoss / Eaton-GR Pump (BQR) is a fixed displacement external gear pump suited for use in tractors, harvesters, lift trucks, compactors, sweepers, and fan drive systems, among other equipment types. Its construction supports both steering circuits and auxiliary work circuits, making it a versatile choice across a range of machine configurations.

Key design attributes include reduced noise and vibration, along with improved volumetric and mechanical efficiency. The pump is field reversible for direction, providing installation flexibility without requiring a separate unit for opposing rotation. A minimum working temperature rating of -20° supports cold-weather service environments. Width is 5.12 inches. This unit carries the Char-Lynn brand association within the Danfoss / Eaton product family.

SKU: 26010-RAB

Supplier Part Number (MPN): 26010-RAB

Specifications

Brand
Danfoss
Design Code
A
Dimensions
5.16 in L x 5.12 in W x 4.74 in H
Gear Type
Single-Stage
Housing Color
Black
Housing Material
Aluminum
Identification
Standard
Inlet Size
1-5/16-12
Inlet Type
SAE O-ring
Model
26010
Mounting Type
2-Bolt Flanged
Outlet Size
7/8-14
Outlet Type
SAE O-ring
Rotation
Clockwise (Right-Hand)
Series
26 Series
Shaft Type
11 Teeth Splined

Product Questions & Answers (2)

Question by: Troy J on Jul 31, 2025, 6:49 PM
pump says it's field reversible, does that mean I can swap the rotation direction myself out in the shop without sending it off somewhere?
Answer by: Customer Support on Aug 1, 2025, 6:52 PM
Yeah, that's exactly what it means. You can change the pump's rotation direction right there in your shop without having to send it out or order a separate unit for the opposite rotation. That kind of flexibility comes in handy when you're fitting it into a machine that runs the drive shaft a different direction than what you originally planned for.
Question by: Dean D on Feb 17, 2026, 6:19 PM
Reckon this'll hold up okay in cold weather?
Answer by: Customer Support on Feb 19, 2026, 6:49 AM
The minimum working temperature for this Danfoss / Eaton-GR pump is -20 degrees, so it's built to handle colder conditions.