DANFOSS / EATON ACNAR16ESD0140000AAR0K0A

Description & Features

Ideal for demanding tasks in tractors, harvesters, and machine tools, the Danfoss / Eaton ACNAR16ESD0140000AAR0K0A Series 26 Gear Pump delivers exceptional performance with reduced noise and vibration. Its field-reversible pump direction and improved volumetric and mechanical efficiency ensure versatile functionality across various applications, including steering circuits, compactors, and sweepers. This hydraulic fixed displacement external gear pump features a high inlet pressure capacity of 1.7 bar (25 lbf/in²) with a robust seal and retaining ring, making it reliable under challenging conditions.

Designed for use in lift trucks, fan drive systems, and auxiliary work circuits, this pump is engineered to withstand a minimum working temperature of -20°C, offering reliability in diverse environments. With a compact width of 5.12 inches, it fits seamlessly into existing systems. Its Char-Lynn ECC brand ensures compatibility and performance consistency, making it a valuable asset in industrial use.

SKU: 26016-RAK

Supplier Part Number (MPN): 26016-RAK

Specifications

Brand
Danfoss
Gear Type
Single-Stage
Housing Color
Green
Housing Material
Aluminum
Inlet Size
1-1/16-12
Inlet Type
SAE O-ring
Model
26016
Mounting Type
4-Bolt Flanged
nmfc
125820
Number of Tang
8
Outlet Size
3/4-16
Outlet Type
SAE O-ring
Port Location
Rear
Rotation
Clockwise (Right-Hand)
Series
26 Series
Shaft Type
Straight Keyed
Special Features
High Inlet Pressure, 1.7 bar [25 lbf/sq-in] Max Seal with Retaining Ring

Product Questions & Answers (1)

Question by: Pete B on May 12, 2025, 12:13 PM
Got a Series 26 pump running on a harvester right now that's getting loud. Would this one run quieter, or is that more of a mount and hydraulic connections issue?
Answer by: Customer Support on May 13, 2025, 1:10 PM
Reduced noise and vibration is actually a built-in design characteristic of this Series 26 pump, not just a side effect of how it's mounted. So yes, swapping to this unit can make a real difference on its own. That said, if your current setup has loose mounts or aerated fluid, those issues will still show up regardless of which pump you run. The pump itself is engineered to operate more quietly than older designs in this series, which makes it a solid starting point if noise is your main concern.

Tell us what you need and we'll get back to you.