DANFOSS / EATON ACNBR06AAA020AJACA00000A

Description & Features

Designed for fixed-displacement external gear pump applications, the Danfoss / Eaton ACNBR06AAA020AJACA00000A is a Series 26 gear pump built for reliable hydraulic output across a broad range of mobile and industrial equipment. Rated for a minimum working temperature of -20°C, it is suited to demanding environments where consistent performance is required through cold-start conditions.

Field-reversible pump direction provides installation flexibility, while reduced noise and vibration characteristics make it a practical fit for operator-sensitive environments. Improved volumetric and mechanical efficiency support consistent output across varying load conditions.

Typical applications include tractors and harvesters, machine tools, steering circuits, compactors, sweepers, rotary and reel mowers, lift trucks, fan drive systems, and auxiliary work circuits, covering a wide range of mobile and stationary hydraulic installations.

SKU: 26206-RAA

Supplier Part Number (MPN): 26206-RAA

Specifications

Brand
Danfoss
Gear Type
Single-Stage
Housing Material
Aluminum
Inlet Size
1-5/16-12
Inlet Type
SAE O-ring
Model
26206
Mounting Type
2-Bolt Flanged
nmfc
125820
Outlet Size
7/8-14
Outlet Type
SAE O-ring
Rotation
Clockwise (Right-Hand)
Segment Code
C
Series
26 Series
Shaft Pitch
16/32
Unit Type
Flow Divider

Product Questions & Answers (2)

Question by: Billy W on Aug 3, 2025, 2:40 PM
Can this gear pump handle cold weather starts without issues?
Answer by: Customer Support on Aug 5, 2025, 7:33 AM
It's rated for a minimum working temperature of -20°C, so it should perform reliably even when it's pretty cold out.
Question by: Curt J on Dec 24, 2025, 4:10 PM
pump says field reversible, does that mean I can flip the rotation direction myself out in the shop without sending it back somewhere?
Answer by: Customer Support on Dec 26, 2025, 12:24 PM
That's what it means. The Series 26 is built so the rotation direction can be changed in the field without any special tooling or factory involvement. That's a real practical advantage when you're fitting it into a circuit that runs opposite of what the standard configuration expects. Saves time and keeps the job moving.