DANFOSS / EATON ACNBR10ABA020AMAPA00000A

Description & Features

Designed for demanding mobile and industrial hydraulic applications, the Danfoss / Eaton ACNBR10ABA020AMAPA00000A is a Series 26 fixed displacement external gear pump built to perform across a broad range of equipment types. It is suited for use in tractors and harvesters, lift trucks, fan drive systems, steering circuits, compactors, sweepers, rotary and reel mowers, machine tools, and auxiliary work circuits.

The pump features reduced noise and vibration alongside improved volumetric and mechanical efficiency. Field-reversible pump direction adds installation flexibility, allowing the unit to be configured for different circuit requirements without sourcing an alternate part. A minimum working temperature rating of -20° supports operation in cold-weather environments. The Char-Lynn sub-brand association reflects Danfoss / Eaton's established heritage in mobile hydraulic components.

SKU: 26210-RAA

Supplier Part Number (MPN): 26210-RAA

Specifications

Application
Tractors & harvesters, Machine tools, Steering circuits, Compactors, Sweepers, Rotary & reel mowers, Lift trucks, Fan drive systems, Auxiliary work circuits
Brand
Danfoss – Hydraulics
Brand
Char-Lynn
Pack Size
1.00
UOM
EA
Features
Reduced noise and vibration|Improved volumetric and mechanical efficiency|Field reversible pump direction
ICC
Hyd Fixed Dis External Gear Pump
Language
English
Minimum Working Temperature
-20
Net Pack Quantity Units
EA
NMFC
125820
Product Width
5.12
Special Features
None
Sub Brand
None
Supplier Part Number
26210-RAA
Product Weight
10.00 lbs

Product Questions & Answers (2)

Question by: Roger M on May 22, 2025, 10:22 AM
pump'll work on a fan drive circuit or is it really only meant for steering and ground drive stuff?
Answer by: Customer Support on May 23, 2025, 9:16 PM
Fan drive systems are actually listed as one of the supported applications for this pump, alongside steering circuits, lift trucks, compactors, and several others. The Series 26 fixed displacement design handles a pretty wide range of mobile and industrial hydraulic uses, so running it on a fan drive setup is well within what it's built for.
Question by: Wayne A on May 30, 2025, 7:48 PM
Reckon this fella can handle cold weather without conking out?
Answer by: Customer Support on Jun 1, 2025, 12:51 PM
Operation in cold environments is supported. This pump has a minimum working temperature rating of -20 degrees.