DANFOSS / EATON ACMAL069906AB0500010000A0000CD0B

Description & Features

A fixed displacement external gear pump designed for mobile and industrial hydraulic circuits, the Danfoss / Eaton ACMAL069906AB0500010000A0000CD0B is part of the Series 26 family and carries the Char-Lynn brand designation. It is rated for a minimum working temperature of -20°C, making it suitable for cold-weather equipment deployment.

This pump is well-suited to a broad range of equipment types, including tractors, harvesters, lift trucks, compactors, sweepers, rotary and reel mowers, machine tools, fan drive systems, and steering circuits. Key design attributes include reduced noise and vibration, improved volumetric and mechanical efficiency, and a field-reversible pump direction, a practical feature that simplifies installation and servicing in the field without requiring additional components.

SKU: 26506-LAM

Supplier Part Number (MPN): 26506-LAM

Specifications

Brand
Danfoss
Gear Type
Multi-Stage
Housing Color
Blue
Housing Finish
Primer
Housing Material
Aluminum
Inlet Type
SAE O-ring
Model
26506
Mounting Type
2-Bolt Flanged
Outlet Type
SAE O-ring
Rotation Direction
Counterclockwise
Series
26 Series

Product Questions & Answers (2)

Question by: Dustin H on May 23, 2025, 8:00 PM
Will this gear pump work alright on my tractor, doing some heavy lifting and running attachments?
Answer by: Customer Support on May 25, 2025, 10:32 AM
This Danfoss / Eaton Series 26 gear pump is well-suited for tractors and harvesters, as well as other equipment that puts hydraulics to the test.
Question by: Scott M on Dec 8, 2025, 6:13 PM
pump says it's field reversible -- what does that actually mean when you're trying to get it installed on something?
Answer by: Customer Support on Dec 10, 2025, 9:17 AM
Rotation direction on this pump can be swapped without pulling extra parts or making modifications. If the hydraulic connections on your machine runs the opposite direction from the factory default, you can reverse it right there during install. Saves a real headache when you're fitting it into a tight application where the ports need to land a certain way.