DANFOSS / EATON ACMCR089904AB01002500APA0A00000B

Description & Features

Designed for demanding industrial applications, this gear pump excels in tractors, harvesters, machine tools, and more. The Danfoss / Eaton ACMCR089904AB01002500APA0A00000B offers remarkable efficiency and reduced noise and vibration, making it an ideal choice for environments where performance and reliability are critical. Its field-reversible pump direction adds versatility, allowing for seamless integration into various systems.

With a robust build, this pump withstands minimum temperatures as low as -20 degrees Celsius, ensuring dependable operation in challenging conditions. Its compact size, with a width of 5.12 inches, facilitates easy installation in constrained spaces. The product is a member of the Char-Lynn brand family, known for quality and innovation in hydraulic solutions.

SKU: 26508-RAE

Supplier Part Number (MPN): 26508-RAE

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X24007
Application
Tractors & harvesters, Machine tools, Steering circuits, Compactors, Sweepers, Rotary & reel mowers, Lift trucks, Fan drive systems, Auxiliary work circuits
Brand
Danfoss – Hydraulics
Brand
Char-Lynn
Pack Size
1.00
UOM
EA
Features
Reduced noise and vibration|Improved volumetric and mechanical efficiency|Field reversible pump direction
ICC
Hyd Fixed Dis External Gear Pump
Language
English
Minimum Working Temperature
-20
Product Width
5.12
Special Features
None
Sub Brand
None
Supplier Part Number
26508-RAE
Product Weight
17.00 lbs

Product Questions & Answers (1)

Question by: Billy B on Jun 19, 2025, 7:31 PM
pump says it's field reversible, what does that actually mean for someone swapping this into an existing setup?
Answer by: Customer Support on Jun 21, 2025, 3:30 PM
Reversing the pump direction in the field means you can change which port acts as the inlet and which acts as the outlet without sending the unit back for modification or buying a different model. Practically speaking, if your system runs the shaft clockwise and you need counterclockwise, or the hydraulic connections on your machine is routed opposite to what a standard configuration expects, you can make that adjustment on-site. That kind of flexibility saves real time when you're retrofitting this into a machine that wasn't originally spec'd around this unit.