VICKERS-DPS2-12-T-F-0-160valV

Description & Features

Engineered for demanding mobile and industrial applications, the Vickers-DPS2-12-T-F-0-160valV Logic Element Valve by Vickers offers robust performance across harvesters and refuse haulers. With the capability to withstand pressures up to 350 bar (5000 psi) and a flow rate of 114 litres per minute, this poppet-style valve enhances machine efficiency while streamlining the design process and reducing manufacturing costs. Its compact design with a width of 1.4 inches ensures seamless integration into various systems.

As part of the Vickers DPS2-12 Series, this logic element valve supports a maximum flow of 400 L/min (100 USgpm), making it suitable for high-demand scenarios. Known for its reliability, the valve is a crucial component in optimizing hydraulic system performance, ensuring consistent operation under high pressure and flow conditions.

SKU: 302AA00019A

Supplier Part Number (MPN): 302AA00019A

Specifications

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 400 L/min (100 USgpm)|Enhance machine performance|Shorten design process and minimize manufacturing costs
Flow Rate1
114 litre per minute
ICC
SICV Logic Elements Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1.40
Special Features
None
Style
Poppet
Sub Brand
Vickers
Supplier Part Number
302AA00019A
Product Weight
0.68 lbs

Product Questions & Answers (2)

Question by: Kirk A on Jun 11, 2025, 7:56 AM
runs up to 350 bar on our refuse haulers pretty regular, this valve gonna hold up at that pressure without giving us grief?
Answer by: Customer Support on Jun 12, 2025, 7:23 PM
At 350 bar (5000 psi), that's exactly the rated maximum pressure for this valve, so running your refuse haulers at that level is well within what it's built for. The poppet-style design handles high-pressure conditions consistently, which is part of why this series gets used in demanding mobile applications like haulers in the first place. Just keep in mind that 350 bar is the ceiling, not a suggested cruising pressure, so staying at or below that keeps things running smooth over the long haul.
Question by: Hubert B on Nov 24, 2025, 6:22 PM
If I'm usin' this in a mobile setup, what kind of flow rate should I expect?
Answer by: Customer Support on Nov 26, 2025, 5:35 PM
Realistically, you're lookin' at around 114 liters per minute with this valve, but it's designed to handle peaks up to 400 L/min in high-demand situations.