Designed for demanding mobile and industrial hydraulic circuits, the Vickers DPS2-12-P-F-0-160Valv is a spool-style logic element from the Danfoss/Eaton DPS2-12 series, built to handle flows up to 114 litres per minute and rated to 350 bar (5,000 psi). These performance parameters make it well suited for high-pressure circuit integration in harvesters, refuse haulers, and a broad range of mobile equipment.
As a logic element valve, the DPS2-12 functions as a slip-in cartridge-type component that supports flexible circuit design, helping to reduce manifold complexity and manufacturing lead time. The spool construction provides reliable directional control within compact integrated circuit configurations. With a series ceiling of 400 L/min (100 USgpm) capacity across the DPS2-12 range, this unit fits within a scalable product family for varied flow requirements across industrial and mobile applications.
SKU: 302AA00025A
Supplier Part Number (MPN): 302AA00025A
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00569X02727
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 400 L/min (100 USgpm)|Enhance machine performance|Shorten design process and minimize manufacturing costs
Flow Rate1
114 litre per minute
ICC
SICV Logic Elements Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1.40
Special Features
None
Style
Spool
Sub Brand
Vickers
Supplier Part Number
302AA00025A
Product Weight
0.68 lbs
Product Questions & Answers (2)
Question by: Tommy P on Apr 4, 2026, 7:27 AM
How much flow can this Vickers valve handle, roughly? I'm workin' on a setup that needs a good bit of juice.
Answer by: Customer Support on Apr 6, 2026, 6:44 AM
This Vickers DPS2-12-P-F-0-160Valv logic element can handle flows up to 114 liters per minute. It's part of a series that tops out at 400 L/min, so there's some scalability there if you need it down the road.
Question by: Hank M on Nov 9, 2025, 5:30 PM
Running a refuse hauler and need a logic element that can keep up with high-pressure demand. This unit rated for 5,000 psi?
Answer by: Customer Support on Nov 11, 2025, 8:22 AM
Rated at 350 bar, which works out to 5,000 psi, so yeah, it's built for exactly that kind of high-pressure circuit work. Flow capacity on this specific unit hits 114 litres per minute, and the broader DPS2-12 series tops out at 400 L/min across the range. Refuse haulers are actually one of the listed applications for this valve, so it lines up well with that kind of duty.