Designed for mobile and industrial hydraulic circuits, this 2-way, 2-position normally closed solenoid valve handles flow rates up to 132 litres per minute and is rated to 350 bar (5,000 psi). The 3/4-inch port size and 12-volt DC actuation make it well suited for demanding mobile applications including harvesters and refuse haulers, where reliable directional control is required under high-pressure conditions.
The VICKERS-SV13-16-C-S12T-12DGH is part of the Vickers by Danfoss SV13-16-C/CM Series, built with hardened and ground steel construction for durability in continuous-duty environments. Its compact form factor supports installation in space-constrained hydraulic systems without compromising performance.
SKU: 303AA00631A
Supplier Part Number (MPN): 303AA00631A
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00569X02815
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 227 L/min (60 USgpm)|Reliable, economical and compact|Hardened and ground steel
Flow Rate1
132 litre per minute
ICC
SICV Solenoid Valves
Language
English
Port Size
3/4
Product Width
2
Special Features
None
Style
2-Way 2-Position Normally Closed
Sub Brand
Vickers
Supplier Part Number
303AA00631A
Voltage
12 volt
Product Weight
5.85 lbs
Product Questions & Answers (2)
Question by: Judy C on Jun 8, 2025, 9:12 PM
Will this valve hold up if I'm running it pretty much non-stop all day long?
Answer by: Customer Support on Jun 10, 2025, 2:25 PM
Hardened and ground steel construction makes this Vickers valve suitable for continuous-duty environments. It's built to handle demanding applications.
Question by: Lance A on Nov 4, 2025, 3:11 PM
Running a 3/4-inch line on a refuse hauler and need a normally closed solenoid that'll hold up at high pressure. This one rated for that kind of work?
Answer by: Customer Support on Nov 6, 2025, 6:34 AM
Rated to 350 bar, which is 5,000 psi, so high-pressure mobile applications are exactly what it's built for. The normally closed configuration means flow stays blocked until the solenoid energizes, which is what you want for safety on equipment like refuse haulers. The 12-volt DC coil fits standard mobile electrical systems, and the hardened and ground steel construction is meant to hold up in continuous-duty environments rather than light or intermittent use.