VICKERS FR5-8-F-0-0.23

Description & Features

The VICKERS FR5-8-F-0-0.23 is a fixed pressure compensated flow regulator ideal for mobile and industrial applications, including use in harvesters and refuse haulers. This Vickers by Danfoss / Eaton flow control valve features a 10 litre per minute flow rate.

With a reliable, economical, and compact design, this flow control valve offers a perfect balance of pressure and flow, capable of operating up to 350 bar (5000 psi) and 350 L/min (92 USgpm).

SKU: 305AA00144A

Supplier Part Number (MPN): 305AA00144A

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X09741
Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
10 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
0.87
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
305AA00144A
Product Weight
0.12 lbs

Product Questions & Answers (2)

Question by: Judy L on Jun 20, 2025, 6:16 PM
Just making sure, this flow regulator will work on my harvester?
Answer by: Customer Support on Jun 22, 2025, 1:27 PM
Application-wise, yes, this Vickers flow control valve is listed as being suitable for harvesters.
Question by: Chad C on Dec 29, 2025, 2:22 PM
Flow rate on this one is listed at 10 LPM, that right for a refuse hauler setup, or is that gonna be too low for most of them rigs?
Answer by: Customer Support on Dec 30, 2025, 8:44 PM
For refuse hauler applications, 10 litres per minute is the regulated output flow on this valve. Keep in mind the valve itself can handle system flows up to 350 L/min (92 USgpm) at pressures up to 350 bar (5000 psi), so it's not a bottleneck on the system side. The 10 LPM figure is the fixed compensated flow it delivers downstream, which suits auxiliary circuits that need a consistent, controlled rate regardless of load or pressure variation. Whether that matches your specific circuit demand depends on what function you're feeding, but the valve is a known fit for refuse hauler use.