VICKERS FR5-10-F-0-1.25

Description & Features

The Vickers FR5-10-F-0-1.25 is a fixed pressure compensated flow regulator valve suitable for demanding mobile and industrial applications, as well as use in harvesters and refuse haulers.

This Vickers flow control valve offers a perfect balance of pressure and flow within a reliable, economical, and compact design. It handles a flow rate of 23 liters per minute with a maximum pressure of 350 bar (5000 psi) and 350 L/min (92 USgpm).

SKU: 305AA00145A

Supplier Part Number (MPN): 305AA00145A

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X09743
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
23 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
305AA00145A
Product Weight
0.26 lbs

Product Questions & Answers (2)

Question by: Peggy H on Aug 29, 2025, 6:39 PM
Hey, I'm looking for a flow control valve for a harvester, reckon this Vickers one would do the trick?
Answer by: Customer Support on Aug 31, 2025, 8:00 AM
This FR5-10 series valve is definitely suitable. It's designed for use in harvesters, as well as refuse haulers and other mobile or industrial applications.
Question by: Roger W on May 4, 2025, 6:40 PM
What kind of flow rate does this valve actually put out, and is it fixed or can you adjust it on the fly?
Answer by: Customer Support on May 6, 2025, 6:59 AM
Fixed pressure compensated means the flow rate is set and stays consistent regardless of pressure fluctuations in the system. On this particular valve, that fixed rate is 23 liters per minute. You're not going to dial it up or down in the field. It holds that setting while the system handles pressures up to 350 bar, which works out to 5000 psi. The 350 L/min figure refers to the maximum system flow capacity, not the regulated output. Good fit when you need repeatable, steady flow without manual adjustment.