Designed for mobile and industrial hydraulic circuits, the Vickers FR5-10V-F-0-3.50 is a fixed pressure compensated flow regulator rated for demanding environments including harvesters and refuse haulers. It maintains consistent flow output regardless of load-induced pressure variations, making it well suited where stable flow control is a priority.
Part of the Vickers FR5-10 series from Danfoss/Eaton, this valve operates at up to 350 bar (5,000 psi) with a series capacity of up to 350 L/min (92 USgpm). The unit's flow rate is set at 23 litres per minute. Its compact, economical construction keeps installation straightforward in space-constrained mobile equipment and industrial machinery alike.
SKU: 305AA00163A
Supplier Part Number (MPN): 305AA00163A
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X09757
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
23 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Special Features
None
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
305AA00163A
Product Weight
0.26 lbs
Product Questions & Answers (2)
Question by: Darryl B on May 11, 2025, 9:26 AM
What kind of machine would this be good for? Like, what's its main purpose?
Answer by: Customer Support on May 12, 2025, 8:14 PM
Designed for use in both mobile and industrial hydraulic systems, this flow regulator is a solid choice where you need consistent flow, no matter the pressure changes. Think harvesters or even refuse trucks.
Question by: Wes E on Feb 22, 2026, 11:16 AM
Flow rate on this one is set at 23 litres per minute, right? Just want to make sure before I order it for our harvester setup.
Answer by: Customer Support on Feb 23, 2026, 1:11 PM
That's correct. The flow rate on this unit is fixed at 23 litres per minute and cannot be adjusted. It's pressure compensated, so it holds that output steady even when load-induced pressure changes happen in the circuit. For a harvester application that's exactly the kind of stability this valve is built around.