Vickers V20 1P12S 1A11

Description & Features

Designed for demanding industrial applications, the Vickers V20 1P12S 1A11 is a cast iron vane pump built for consistent performance across metal cutting, plastic injection molding, oil and gas, dump truck, and wheel loader applications. It delivers a flow rate of approximately 88.7 litres per minute, making it well-suited for mid-to-high-flow hydraulic circuits.

The V20 Series uses a pressure-balanced, modular 12-vane design that reduces noise and minimizes flow pulsation, two characteristics that matter in precision manufacturing and mobile equipment environments. Cast iron construction provides durability under sustained operating pressures, and the modular configuration supports flexibility across a wide range of available displacements within the series.

SKU: 393722-1

Supplier Part Number (MPN): 393722-1

Specifications

Brand
Vickers by Danfoss
Cover Type
Standard
Dimensions
8.46 in L x 5.12 in W x 4.79 in H
Drive Shaft Type
Straight Keyed
Housing Material
Iron
Inlet Type
NPT
Mounting Type
Flanged
Outlet Size
1-1/16-12
Outlet Type
Threaded
Rotation Direction
Opposite Inlet
Seal Material
Buna-N
Seal Type
Standard
Series
V20 Series
Shaft Seal and Bearing
Single Lip Seal and Sealed Bearing
Vane Type
Balanced

Product Questions & Answers (2)

Question by: Shane W on Apr 9, 2025, 6:36 PM
Will this here pump hold up okay on a dump truck application?
Answer by: Customer Support on Apr 11, 2025, 5:11 PM
For dump truck applications, the Vickers V20 series is built with a durable cast iron construction designed to withstand sustained operating pressures.
Question by: Lee T on Nov 8, 2025, 12:44 PM
Running a wheel loader that sees pretty heavy daily use. This pump rated for that kind of continuous work, or is it more of a light-duty setup?
Answer by: Customer Support on Nov 10, 2025, 6:58 AM
Cast iron construction is what you want for sustained hydraulic work, and that's exactly what this pump is built from. The V20 series is listed for wheel loader applications specifically, so it's not a light-duty unit. The pressure-balanced vane design also helps it run quieter and with less flow pulsation over long cycles, which matters when equipment is working hard through a full shift.

Tell us what you need and we'll get back to you.