VICKERS 2CFD50-20S

Description & Features

Designed for demanding mobile and industrial environments, the Vickers 2CFD50-20S is a spool-style flow control valve rated for pressures up to 350 bar (5,000 psi) and flow rates up to 350 L/min (92 USgpm). With a nominal flow rate of 40 litres per minute, it delivers precise flow regulation in a compact, economical package.

Part of the Eaton Vickers 2CFD50 Series, this valve is well suited to harvesters, refuse haulers, and a range of mobile and industrial hydraulic circuits where reliable flow control is required. The spool configuration supports consistent performance across varying pressure conditions, making it a practical choice for equipment that operates under fluctuating load demands.

SKU: 405AA00037A

Supplier Part Number (MPN): 405AA00037ASP

Alternate Part Numbers: 2CFD50-20S

Specifications

Alternate Part Numbers
Alternate Part Number 2CFD50-20S, Alternate Part Number MINO-00900X23714
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
40 litre per minute
ICC
SICV Flow Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1
Special Features
None
Style
Spool
Sub Brand
Vickers
Supplier Part Number
405AA00037A
Product Weight
0.23 lbs

Product Questions & Answers (3)

Question by: Roy B on Nov 12, 2025, 12:28 PM
got a harvester with a tight valve bank. is this 2CFD50-20S one of them compact spool style flow controls?
Answer by: Customer Support on Nov 14, 2025, 10:38 AM
Compact and spool style are both a good match for this one. It is a Vickers 2CFD50 series flow control valve with a spool style design, and it is positioned as a compact, economical option for mobile and industrial equipment.
Question by: Billy G on Mar 6, 2026, 8:13 AM
Flow rate on this one shows 40 L/min but the series specs mention up to 350 L/min, which number actually applies to this valve?
Answer by: Customer Support on Mar 7, 2026, 1:32 PM
The 350 L/min figure reflects the broader 2CFD50 series ceiling, meaning that's the maximum the platform is rated to handle across configurations. This specific unit, the 2CFD50-20S, is rated at 40 litres per minute. Those are two different numbers serving two different purposes, and the 40 L/min is what applies to your actual application when sizing this valve.
Question by: Carl W on Mar 27, 2025, 6:44 PM
Wondering if this Vickers flow control valve would be a good swap for harvesters?
Answer by: Customer Support on Mar 29, 2025, 6:38 AM
Its applications cover harvesters, refuse haulers, and both mobile and industrial uses, so it should be suitable.