VICKERS 2520VQ21E11 11CC20

Description & Features

Designed for high-pressure and high-speed applications, the Vickers series vane pump offers exceptional durability and efficiency. With a flow rate of 148.69 liters per minute, it is ideal for use in power steering systems, small industrial units, and presses. The pump is constructed from robust cast iron, ensuring a longer operating life and outstanding volumetric efficiency.

The VICKERS 2520VQ21E11 11CC20 is part of the renowned 2520VQ series, known for its reliability and performance in demanding environments. Equipped with Buna-N seals, this pump is engineered to withstand rigorous operational conditions. Its compact dimensions, with a product width of 6.88 inches, make it versatile for various hydraulic applications.

SKU: 430185-7

Supplier Part Number (MPN): 430185-7

Specifications

Brand
Vickers by Danfoss
Cartridge Type
20 Design
Dimensions
11.69 in L x 6.88 in W x 5.75 in H
Displacement
4.1 cu-in Shaft, 2.2 cu-in Cover
Drive Shaft Type
Splined
Flow Rate
21 gpm Shaft, 11 gpm Cover
Housing Material
Iron
Maximum Operating Pressure
2500 psi
Rotation Direction
Anti-Clockwise, Clockwise
Seal Material
Buna-N
Series
2520V Series
Vane Type
Fixed Displacement and Balanced

Similar Products

Model Number Rotation Direction Price Action
VICKERS 2520VQ21E11 11CC20

430185-3

Clockwise

Product Questions & Answers (2)

Question by: Jerry M on Mar 12, 2026, 11:03 AM
cast iron build on this one -- does that hold up alright in higher pressure setups or is that more of a wear concern over time?
Answer by: Customer Support on Mar 13, 2026, 9:21 PM
Cast iron is actually well suited for demanding hydraulic work. It handles the mechanical stress of high-pressure, high-speed operation without flexing the way lighter housings can. The material contributes directly to the longer service life this pump is built around, so for press applications or industrial units pushing hard, the cast iron construction is a feature, not a liability.
Question by: Gene D on Nov 15, 2025, 3:31 PM
Reckon this'd be alright for a power steering setup on an old farm truck?
Answer by: Customer Support on Nov 17, 2025, 6:52 AM
Real-world usage involves power steering systems, along with small industrial units and presses. Just make sure your system's flow rate requirements are in line with the pump's 148.69 liters per minute.