The 06MP-06FP-06FP STREET TEE manufactured by Brennan Industries Inc is a high-quality forged steel tee designed for industrial applications requiring robust and reliable components. With a centerline length of 1.220 mm for centerline 1 and 1.020 mm for centerline 2 this street tee offers precision connectivity for complex systems.
Engineered to handle a maximum dynamic pressure of up to 6 000 PSI this component ensures durability under demanding conditions. The overall length of the tee is 1.020 mm making it suitable for compact installations where space efficiency is essential.
The thread specifications conform to SAE J476 with all threads being 3/8-18 size including Male NPTF for Thread B1 and Female NPTF for both Thread 3 and Thread B2. The use of steel forging as the raw material guarantees high structural integrity and longevity.
Supplier Part Number: 5602-06-06-06-FG
California Residents: PROP-65 WARNING
Loading related products…
Specifications
Brand
Brennan Industries Inc
Brand
Brennan Industries
Pack Size
1.00
UOM
EA
Supplier Part Number
5602-06-06-06-FG
Product Weight
0.27 lbs
Product Questions & Answers (2)
Question by: Denise W on Sep 16, 2025, 3:50 PM
got a street tee here with one male and two female ends, all 3/8-18. is that what this one is?
Answer by: Customer Support on Sep 18, 2025, 3:40 PM
Threading matches that setup. Thread B1 is 3/8-18 Male NPTF, and the other two ports (Thread 3 and Thread B2) are 3/8-18 Female NPTF, with threads called out to SAE J476.
Question by: Wayne G on Jun 27, 2025, 6:03 AM
Rated for 6,000 PSI dynamic pressure on this thing -- that hold up in a hydraulic system running pretty hard day to day?
Answer by: Customer Support on Jun 28, 2025, 5:11 PM
For most industrial hydraulic setups, 6,000 PSI dynamic pressure is a solid ceiling to work with. Forged steel construction gives it the structural backbone to handle sustained load without the kind of fatigue you'd see in cast or machined alternatives. The forging process produces a denser grain structure, which matters when you're pushing fluid through a tee junction at high pressure repeatedly. Just make sure your line pressure stays within that rated limit and you should get solid service life out of it.