70-100 Series Bronze Ball Valve, 1/2 NPT Ports

Description & Features

Rated for 600 psig WOG (cold non-shock) and 150 psig saturated steam, this bronze ball valve is built for reliable shut-off in demanding industrial fluid control applications. The 70-100 Series Bronze Ball Valve features 1/2 NPT ports and a 0.5-inch orifice diameter, with a Cv factor of 15.0 for consistent flow performance.

The body is cast from B584-C84400 bronze, with a chromium-plated B16 ball and RPTFE seats, stem packing, and stem bearing. A blow-out proof stem design and adjustable packing gland contribute to long-term service integrity. The zinc-plated steel lever includes a vinyl cover for ease of operation. Vacuum service capability extends to 29 in./Hg. Seal kit 70-003-01 is available for maintenance.

SKU: 70-103-01

Supplier Part Number (MPN): 7010301

Alternate Part Numbers: B-6000-1/2, C1EN82

Specifications

CV Factor
15.00
Brand
Conbraco Ind Inc
Brand
Conbraco Ind
Pack Size
1.00
UOM
EA
Orifice Diameter
0.50
Ports
1/2 NPT
Ports
1/2 NPT
Seal Kit
70-003-01
Supplier Part Number
7010301
Alternate Part Numbers
Alternate Part Number B-6000-1/2, Alternate Part Number C1EN82
Product Weight
0.63 lbs

Similar Products

Model Number Ports Orifice Diameter CV Factor Features Seal Kit Price Action
70-100 Series Bronze Ball Valve, 3 NPT Ports

70-100-01 70-100 Series Bronze Ball Valve

3 NPT

2.5

370.0000

70-009-01

70-100 Series Bronze Ball Valve, 1/4 NPT Ports

70-101-01 70-100 Series Bronze Ball Valve

1/4 NPT

0.37

8.4000

70-002-01

70-100 Series Bronze Ball Valve, 3/4 NPT Ports

70-104-01 70-100 Series Bronze Ball Valve

3/4 NPT

0.68

30.0000

70-004-01

70-100 Series Bronze Ball Valve, 1 NPT Ports

70-105-01 70-100 Series Bronze Ball Valve

1 NPT

0.87

43.0000

70-005-01

Product Questions & Answers (2)

Question by: Ross W on Jul 31, 2025, 8:01 AM
What pressure can this valve handle for regular water use?
Answer by: Customer Support on Aug 2, 2025, 6:45 AM
This valve is rated for 600 PSI when handling water and other non-shock liquids at cold temperatures.
Question by: Bobby E on Jul 30, 2025, 1:58 PM
rated for steam service or just water and oil?
Answer by: Customer Support on Aug 1, 2025, 6:00 AM
Saturated steam is covered up to 150 psig, and cold non-shock water/oil/gas service goes up to 600 psig. Worth knowing that the pressure rating does drop at elevated temperatures, so if you're running it hot, account for that in your application.