DANFOSS / EATON VICKERS VMQ TRIPLE VANE PUMP

Description & Features

The Vickers by Danfoss / Eaton VMQ Series Vane Pumps are designed for high-pressure applications where noise reduction is crucial. With a unique wafer plate design, these triple vane pumps ensure efficient operation in demanding environments like oil and gas, metal cutting, and plastic injection molding. Constructed from durable cast iron and featuring Buna-N seals, the pumps offer reliable performance and longevity.

This VMQ3352525 series vane pump supports a flow rate of 69.47 liters per minute, making it suitable for various industrial applications including dump trucks and wheel loaders. The combination of single, double, or triple pump configurations provides flexibility in system design, ensuring compatibility with a wide range of hydraulic systems. The Vickers sub-brand within Danfoss / Eaton signifies a commitment to quality and innovation in hydraulic solutions.

SKU: 716-0077-032

Supplier Part Number (MPN): 716-0077-032

Specifications

Cartridge Type
32 Design
Dimensions
21.74 in L x 8.39 in W x 7.65 in H
Displacement
6.83 cu-in Front Section, 2.75 cu-in Middle Section, 1.58 cu-in Rear Section
Drive Shaft Type
Keyed
Flow Rate
38.6 to 72.02 gpm , 47.6 to 86.18 gpm
Frame Size
35 Front, 25 Middle, 25 Rear
Housing Material
Iron
Maximum Operating Pressure
4000 psi
Mounting Type
Flanged
Rotation Direction
Clockwise
Seal Material
Buna-N
Series
VMQ3 Series
Speed Rating
1800 rpm at 120 deg F, 2400 at 120 deg F

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Hubert P on Apr 11, 2025, 8:33 PM
Hey, can you run these pumps all day long or are they more for intermittent use?
Answer by: Customer Support on Apr 13, 2025, 6:37 AM
Designed for demanding environments, the VMQ series vane pumps are suitable for continuous operation in applications like oil and gas or plastic injection molding, where consistent hydraulic pressure is needed.