VICKERS-DG4V4-01-31C-M-U-D7-DS5-10

Description & Features

Designed for robust industrial applications, the Vickers-DG4V4-01-31C-M-U-D7-DS5-10 directional control valve excels in environments such as die casting, machine tools, and marine/offshore settings. Its three- or four-way configuration allows versatile directional control, making it suitable for a variety of hydraulic systems. The valve supports a substantial flow rate of 115 liters per minute, ensuring efficient operation in demanding tasks.

Easily mountable on industry-standard surfaces, this Vickers valve is part of a broad range of models tailored to meet specific application needs. Constructed with Buna-N seal material, it ensures durability and reliable performance. With a wattage of 30, this unit is engineered for efficiency without compromising on power. Ideal for use in turbines, presses, and test equipment, it is a versatile option for controlling hydraulic flow.

SKU: 831AN00079A

Supplier Part Number (MPN): 831AN00079A

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X62644
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Three- or four-way directional control|Easily mountable on industry-standard surfaces|Thousands of models to suit all applications
Flow Rate1
115 litre per minute
ICC
IV Directional Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
2.84
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
831AN00079A
Wattage
30
Product Weight
13.20 lbs

Product Questions & Answers (1)

Question by: Bobby H on Jun 28, 2025, 4:47 PM
What kind of hydraulic fluids work best with that Buna-N seal?
Answer by: Customer Support on Jun 29, 2025, 9:09 PM
Given the Buna-N seal material, this Vickers valve is well-suited for use with petroleum-based hydraulic fluids. Keep in mind that compatibility can vary, especially with synthetic fluids, so always double-check fluid specifications.